FKD Series Counter-Rotating Mine Ventilation Fan for Underground and Tunnel

The FKD Series Mine Ventilation Fan is a counter-rotating axial flow ventilation system specifically engineered for underground mining, tunnel excavation, and industrial airflow management. This high-pressure mining ventilation fan enhances dust control, methane extraction, and air circulation in coal mines, hard rock mines, and subsurface projects. Designed for low noise, stable operation, and extended air supply distances, it is ideal for auxiliary ventilation, booster ventilation, and emergency ventilation. Its advanced engineering ensures efficient airflow control and reliability in harsh underground environments.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Explosion proof
  • Compact
  • Built-in muffler
  • unique tracking order for each fan. 
  • three layer anti-corrossion painting. 
  • largest diameter 5meters! 
  • Each hub is annealed to remove internal stress.Durable enough. 
  • Orthogonal 3D Twisted Blade Technology of Bend and Sweep Combination,Simulated Dune Principle. 
  • In line with international standards, 1000: 1.5~2.5, to ensure that the impeller works more safely and efficiently. 
FKD Series Counter-Rotating Mine Ventilation Fan for Underground and Tunnel

Product-related News:


DECENT MACHINERY‘12 Custom Mining Ventilation Fans Pass Full Bv Third-Party Full-Condition Tests For Central Asian Copper Mine Project.


FKD Series Counter-Rotating Mine Ventilation Fan for Underground and Tunnel

DECENT MACHINERY Welcomes East African Mining Partners for In-depth Mine Fan Cooperation

FBD Series Explosion-Proof Counter-Rotating Mine Ventilation Fan

DECENT MACHINERY Welcomes Top Southeast Asian Copper Mining Enterprise for Strategic Cooperation Talks,New Partnership Secured

FBD Series Explosion-Proof Counter-Rotating Mine Ventilation Fan

DECENT MACHINERY Forges Long-Term Strategic Partnership with Leading Southeast Asian Mining Conglomerate

FBD Series Explosion-Proof Counter-Rotating Mine Ventilation Fan


The FKD Series High-Pressure Mine Ventilation Fan is developed to provide targeted airflow solutions for underground chambers, mining tunnels, and confined industrial spaces. This counter-rotating axial flow ventilation system plays a critical role in coal mines, hard rock mines, and tunnel construction projects, ensuring consistent and efficient ventilation in underground workspaces.

Key Features of FKD Series Mine Ventilation Fan


  • Optimized airflow performance with a stable characteristic curve and broad high-efficiency range.
  • Low-noise operation and vibration reduction for smooth functionality in underground settings.
  • Extended airflow reach, making it highly effective in deep tunnel and mine ventilation.
  • National patent design with swept-blade counter-rotating axial flow technology (Patent No.: ZL03215439.9).
 


Installation and Operating Conditions


  • The FKD Series Mine Ventilation Fan can be installed on the tunnel floor or securely mounted on tunnel walls. If placed on the ground, the air intake (collector side) must remain free from water and debris.
  • The operational temperature range is -20°C to 40°C, and it is designed for altitudes up to 1000m.
  • The maximum allowable dust concentration in the working environment should not exceed 200mg/m³.
  • The power supply operates at a standard frequency of 50Hz, with voltage options including 380V/660V or 660V/1140V.
Specifications Power (kW) Air Flow (m³/min) Pressure(Pa) Dimensions (mm)
D  L
FKDNo5.0/2×4 2×4 217~145 275~2060 640  1460 
FKDNo5.0/2×5.5 2×5.5 240~161 325~2540 640  1460 
FKDNo5.0/2×7.5 2×7.5 266~178 400~3155 640  1460 
FKDNo5.6/2×7.5 2×7.5 286~188 275~2850 710  1624 
FKDNo5.6/2×11 2×11 324~215 375~3690 710  1624 
FKDNo5.6/2×15 2×15 358~238 440~4560 710  1624 
FKDNo6.3/2×15 2×15 410~237 400~4775 800  1930 
FKDNo6.3/2×18.5 2×18.5 442~256 460~5475 800  1930 
FKDNo6.3/2×22 2×22 468~274 525~6125 800  1930 
FKDNo6.3/2×30 2×30 518~318 640~7310 800  1930 
FKDNo7.1/2×30 2×30 608~352 523~6228 890  2270 
FKDNo7.1/2×37 2×37 652~377 602~7163 890  2270 
FKDNo7.1/2×45 2×45 696~402 686~8161 890  2270 
FKDNo8.0/2×45 2×45 817~473 605~7200 1000  2500 
FKDNo8.0/2×55 2×55 874~506 692~8230 1000  2500 
FKD Series Counter-Rotating Mine Ventilation Fan for Underground and Tunnel
Mine
Underground Mine
Parking Lot
Subway
Metrol
Tunnel

Customer On-site Praise Client Usage Feedback Cooperation Story
Authoritative Third‑party Testing
FAQ
Q : what is the noise level of YBT fans?
A: generally 90dB(A). if connect silencers,can reduce to 70dB(A).
Q : what is the motor brand?
A: ABB/Siemens/WEG...
Q : what is the material of impeller?
A: for safety consideration,we use aluminum impeller.