YS6-45-11 Industrial Centrifugal Fan for Boiler Systems

The YS6-45-11 industrial boiler centrifugal fan is engineered for 2~4 ton per hour boilers, designed to handle various coal types and equipped with dust removal systems. This centrifugal blower delivers maximum pressure efficiency of 86.3% and operates at temperatures up to 250℃, providing optimal performance for industrial boiler systems.

  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
YS6-45-11 Industrial Centrifugal Fan for Boiler Systems

Application

The YS6-45-11 boiler fan is ideal for 2~4 ton per hour industrial boilers, effectively managing coal combustion and removing smoke and dust. Its maximum efficiency reaches 86.3%, making it suitable for boilers with similar air intake conditions, operating up to 250℃.
 

Form

  • 1. This fan features a single-suction structure and is available in three sizes: No.5, No.5.6, and No.6.3. The fan blades can be adjusted to meet different operational requirements.
  • 2. The fan is available in right-hand and left-hand rotations. Right-hand fans rotate clockwise when viewed from the motor end, and left-hand fans rotate counterclockwise.
  • 3. The fan housing allows for outlet angles at 0°, 90°, 180°, and 270°.

 

Structural Characteristics

  • 1. Impeller: Featuring 12 backward-curved blades made from Q345 steel, the impeller is welded and dynamically balanced for smooth, long-term use.
  • 2. Casing: Constructed from welded steel plates into a volute form.
  • 3. Air Inlet: The air inlet is a convergent, streamlined structure and is securely bolted to the casing.
  • 4. Transmission System: The system consists of a high-strength steel shaft, water-cooled bearing box, and coupling, lubricated with high-temperature molybdenum disulfide grease for optimal performance.
  • 5. Flow Control Door: The regulating door allows for precise adjustment of airflow. Lubrication is provided by high-temperature grease to ensure smooth operation under high heat conditions.

 

Performance and Selection

According to the GB/T1236-2000 standard, the fan's performance is tested under conditions where the air intake is at 200℃, and the air density is ρ =0.745kg/m³. If there is a deviation in operating conditions, the performance should be recalculated using the following formula:
 

Full Pressure: YS6-45-11 Industrial Centrifugal Fan for Boiler Systems

 

Air Flow: YS6-45-11 Industrial Centrifugal Fan for Boiler Systems

 

Shaft Power: YS6-45-11 Industrial Centrifugal Fan for Boiler Systems

In this formula, p₁, q₁, P₁ refer to the total pressure, flow rate, and shaft power in the performance table, while p₂, q₂, P₂ are under actual usage conditions. Atmospheric pressure pa and the temperature of the conveying gas (t₂) are critical for calculation. If the motor capacity is not changed, it is important to avoid running the fan at full speed in cold conditions, as it may lead to motor overload and potential damage.

Impeller   Air Flow /(m³/h) Pressure /Pa Moter    Rotating Rate /(r/min) Boiler Capacity /(t/h)
No. Power /kW
YS6-45-11 No.5
No.1 10944
10160
9083
8292
7715
7181
6743
5965
5458
5021
1687
1863
2059
2197
2295
2373
2442
2501
2510
2520
Y132S2-2 7.5  2900 
No.2 9979
9313
8618
7882
7069
6118
5000
4587
1383
1569
1687
1804
1961
2089
2148
2148
Y132S1-2 5.5  2900 
YS6-45-11 No.5.6
No.1 15375
14273
12760
11648
10838
10087
9473
8380
7668
7053
2118
2334
2579
2755
2873
2981
3069
3128
3148
3158
Y160M2-2 15  2900  4
No.2 14019
13082
12107
11073
9931
8595
7024
6444
1736
1971
2108
2265
2461
2618
2697
2697
Y160M1-2   2900  4
YS6-45-11 No.6.3
No.1 18912
17556
15696
14328
13332
12408
11652
10308
9432
8676
2432
2687
2971
3167
3305
3422
3520
3618
3609
3628
Y160L-2 18.5  2900  4
No.2 17244
16092
14892
13620
12216
10572
8640
7927
1991
2265
2422
2599
2824
3010
3099
3099
Y160M2-2 15  2900  4
YS6-45-11 Industrial Centrifugal Fan for Boiler Systems
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch
Category
Get in Touch