Y8-39 & Y9-38 High-Pressure Centrifugal Blowers for Industrial Boilers and Dust Extraction

The Y8-39 and Y9-38 Series High-Pressure Centrifugal Blowers are specifically designed for industrial boilers with capacities ranging from 0.5 to 35t/h, featuring economizers and dust removal systems. With a maximum air intake temperature of 250°C, these Industrial Centrifugal Fans are suitable for various high-temperature applications. Available in right-handed and left-handed versions, the blowers provide multiple outlet angles, ensuring flexibility and efficiency for different installation needs.

  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
Y8-39 & Y9-38 High-Pressure Centrifugal Blowers for Industrial Boilers and Dust Extraction

Application


The Y8-39 and Y9-38 Series Centrifugal Blowers are designed to work with 0.5-35t/h industrial boilers that are equipped with economizers (preheaters) and dust extraction devices. These High-Pressure Centrifugal Fans are also applicable for other boilers with similar air intake requirements and performance characteristics, provided the maximum air intake temperature does not exceed 250°C. An efficient dust removal device with a minimum 85% efficiency should be installed before the induced draft fan to reduce the dust content of the flue gas entering the fan. This not only minimizes environmental pollution but also reduces wear and tear on the fan caused by smoke and dust, thereby extending its service life.
 

Form


  1. 1. The Y8-39 and Y9-38 Centrifugal Fans are single-suction units available in 13 different sizes: No.4, No.4.5, No.5, No.5.6, No.6.3, No.7.1, No.8, No.9, No.10, No.11.2, No.12.5, No.14, and No.16.
  2. 2. The fans can be configured in both right-handed and left-handed orientations. When viewed from the motor end, a clockwise impeller rotation indicates a right-handed fan, while a counterclockwise rotation denotes a left-handed fan.
  3. 3. The fan outlet position is marked by the casing outlet angle, and both right-hand and left-hand configurations can be manufactured with six different outlet angles: 0°, 45°, 90°, 135°, 180°, and 225°.

Structural Characteristics


The Y8-39 and Y9-38 Series Centrifugal Fans are composed of several main components: impeller, casing, air inlet, transmission unit, regulating door, and more.

  1. 1. The impeller is constructed from Q345 (16Mn) steel with a combination of long and short forward-curved blades. The impeller undergoes static and dynamic balance testing to ensure smooth and stable operation.
  2. 2. The casing is made of welded steel plates, forming a volute-shaped design. A dust removal door is included, allowing for easy cleaning of dust deposits to maintain balance and aerodynamic performance.
  3. 3. The air inlet is designed as a streamlined convergent structure and is secured to the front cover assembly with bolts, enhancing airflow efficiency.
  4. 4. The transmission unit consists of the main shaft, water-cooled bearing box, and coupling. The main shaft is made from high-quality steel and uses rolling bearings. Two types of bearing boxes are available: integral and split. Models No.4 to No.6.3 use integral bearing boxes, while models No.7.1 to No.16 use split bearing boxes. Water cooling is required for both types, and water consumption ranges from 0.5 to 1m³/h depending on the working and ambient temperatures. The bearing box is equipped with a thermometer and an oil level indicator. L-AN46 total loss system oil is used as the lubricant, with the oil volume based on the indicated level.
  5. 5. The regulating door controls the airflow range from fully closed (90°) to fully open (0°). The petal-shaped blades are axially installed in front of the air inlet, and the external transmission structure makes adjustments flexible and easy. For optimal operation, the regulating door should be lubricated with high-temperature bentonite grease, ensuring smooth performance at temperatures up to 260℃.


Performance and Selection


  1. 1. To select the appropriate model, users should refer to the performance table based on the desired airflow and total pressure. Alternative motor types may be chosen if the power and speed specifications are compatible; these details should be noted when placing an order.
  2. 2. The total pressure deviation of factory-tested fans should not exceed ±6% at the rated flow rate.
  3. 3. The performance of models No.4 to No.6.3 is based on a flue gas temperature of 220℃ and 200℃, an atmospheric pressure of Pa=101325Pa, and a gas density of ρ=0.713 kg/m³ and 0.745 kg/m³. For models No.7.1 and above, performance is calculated with a gas temperature of 200℃ and 175℃, an atmospheric pressure of Pa=10325Pa, and a gas density of ρ=0.745 kg/m³ and 0.784 kg/m³. If operating conditions deviate from these parameters, the performance should be adjusted using the appropriate conversion formula.

Performance And Optional Parts Of y8-39 Boiler Centrifugal Induced Draft Fan
No. Rotating Speed /(r/min) Full Pressure /Pa Air Flow /(m³/h) Motor Power /kW
4D 2900  2039
2049
3242
3846
2030
1961
1882
4451
5055
5660
5.5 
4.5D 2900  2579
2589
4613
5477
7.5 
2569
2490
2392
6338
7199
8059
11 
5D 2900  3187  6332  11 
3197
3167
7513
8693
15 
3079
2951
9874
11055
18.5 
5.6D 2900  4001  8896  18.5 
4011  10555  22 
3971
3854
3707
12214
13873
15531
30 
6.3D 1450  1265
1265
1255
6333
7514
8695
5.5 
1216
1167
9876
11057
7.5 
2900  5060
5080
12667
15029
37 
5031
4883
4687
17391
19752
22114
55 
7.1D 1450  1647
1686
1647
1608
9066
10756
12446
14136
11 
1539
1441
1333
15827
17517
19207
15 
8D 1450  2088
2147
2098
12969
15387
17805
18.5 
2039
1951
20223
22641
22 
1833
1696
25059
27477
30 
9D 1450  2647
2716
18465
21908
30 
2657
2579
25351
28794
37 
2471
2324
2147
32237
35679
39122
45 

Y8-39 & Y9-38 High-Pressure Centrifugal Blowers for Industrial Boilers and Dust Extraction
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.