The Y6-30 Industrial Boiler Centrifugal Blower is expertly engineered for high-pressure environments, delivering efficient airflow management and boosting boiler combustion efficiency. This industrial centrifugal fan features adjustable air volume and pressure, offering reliable performance across various applications. Built with durable materials, the Y6-30 series provides smooth operation with low noise. Available in both clockwise and counterclockwise rotation, this centrifugal blower is ideal for boiler systems that demand stable airflow and precise control.



The Y6-30 series centrifugal fan includes seven different machine sizes: No. 3.5C, 4.3C, 4.8C, 5.4C, 6.5C, 7.5C, and 8.6C.
This centrifugal blower can rotate in both clockwise and counterclockwise directions. The right-hand or left-hand orientation is defined by how the impeller moves when viewed from the motor’s side. The fan’s outlet can be adjusted to several angles to optimize airflow, with options such as 45°, 90°, 135°, and more.
| (Rotation Speed 2350 r/min, Altitude 0 km, Fan Inlet Temperature 200°C, Fan Inlet Gas Density 0.743 kg/m³, Outlet Equivalent Area 0.128) | |||||
| Flow Rate/(m³/h) | Pressure/Pa | Static Pressure/Pa | Power /kW | Compatible Boiler/(t/h) | Speed Ratio |
| Y6-30-12No.3.50C② | |||||
|
655 745 834 923 1000 1103 1192 |
853 843 834 824 800 765 727 |
803 778 753 725 683 623 561 |
0.75 | 0.2 |
24.6 26.4 28.2 29.9 31.8 34.6 37.3 |
| Y6-30-15No.3.50C② | |||||
|
622 708 792 877 950 1048 1132 |
746 738 730 721 700 669 636 |
701 680 657 631 595 541 487 |
0.75 | 0.2 |
26.5 28.5 30.3 32.2 34.3 37.3 40.2 |
| Y6-30-16No.3.50C② | |||||
|
694 790 884 978 1060 1169 1263 |
992 981 970 959 931 890 846 |
936 908 879 847 800 731 660 |
0.75 | 0.2 |
22.6 24.3 25.9 27.5 29.3 31.8 34.3 |
| Y6-30-12 No.4.30C② | |||||
|
1169 1328 1487 1700 1806 1966 2125 |
1206 1197 1176 1140 1118 1078 1020 |
1136 1107 1063 992 951 880 789 |
1.5 | 0.2 |
24.3 26.1 28.0 30.6 32.0 34.3 37.2 |
| Y6-30-15 No.4.30C② | |||||
|
11l1 1262 1413 1615 1716 1868 2019 |
1055 1047 1029 998 978 943 893 |
992 965 927 865 827 764 684 |
1.5 | 0.2 |
26.1 28.1 30.1 33.0 34.5 37.0 40.1 |
| Y6-30-16 No.4.30C② | |||||
|
1239 1408 1576 1802 1914 2084 2252 |
1403 1393 1368 1326 1301 1254 1187 |
1324 1292 1241 1160 1114 1032 927 |
2.2 | 0.2 |
22.4 24.0 25.7 28.1 29.4 31.6 34.2 |
| Y6-30-12 No.4.80C② | |||||
|
1619 1840 2060 2300 2502 2723 2944 |
1490 1470 1450 1420 1392 1333 1265 |
1404 1358 1310 1246 1186 1089 979 |
2.2 | 0.5 |
24.3 26.2 28.0 30.1 31.8 34.3 37.1 |
| Y6-30-15 No.4.80C② | |||||
|
1538 1748 1957 2185 2377 2587 2797 |
1304 1286 1269 1243 1218 1166 1107 |
1226 1185 1143 1086 1032 945 849 |
1.5 2.2 |
0.2 0.5 |
26.2 28.2 30.2 32.4 34.3 37.0 40.0 |
| Y6-30-16 No.4.80C② | |||||
|
1716 1950 2184 2438 2652 2886 3121 |
1734 1710 1687 1652 1620 1551 1472 |
1637 1585 1530 1456 1388 1276 1151 |
3 | 0.5 |
22.4 24.1 25.7 27.6 29.2 31.5 34.1 |
| ① The reference distance refers to the distance from the noise level measurement point to the center of the opening. When the impeller diameter is ≤1m, the reference distance is 1m; when the impeller diameter is >1m, the reference distance is the impeller diameter. The same applies hereafter. | |||||
| ② When the motor power is less than or exceeds the power required by the fan, a new selection must be made. The same applies hereafter. | |||||















|
|
|
|
| Decent Fan Customer Comment | Impellers Dynamic and Static Balance Test | Centrifugal Fan Factory Tour |
|
|
|
|
| Complete Centrifugal Fan Assembly Guide | Centrifugal Fan Laboratory Testing | High-Performance Centrifugal Fan Unveiled |
|
|
|
|
| Silent and Powerful Centrifugal Fan | Advanced Centrifugal Fan Manufacturing Process | Decent Machinery Fan Production Revealed |