The Y6-30 Industrial Boiler Centrifugal Blower is expertly engineered for high-pressure environments, delivering efficient airflow management and boosting boiler combustion efficiency. This industrial centrifugal fan features adjustable air volume and pressure, offering reliable performance across various applications. Built with durable materials, the Y6-30 series provides smooth operation with low noise. Available in both clockwise and counterclockwise rotation, this centrifugal blower is ideal for boiler systems that demand stable airflow and precise control.

  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
Y6-30 Industrial Boiler High-Pressure Centrifugal Blower Fan

Application

In modern industries, boiler systems come in multiple configurations and are often influenced by varying coal quality. Additionally, after integrating heat recovery and dust removal systems, inadequate draft is a common issue that can impact boiler efficiency. The Y6-30 series high-pressure centrifugal blower has been designed to address this problem, maintaining the proper pressure and ensuring optimal combustion. This centrifugal fan is tailored for industrial boiler applications, delivering precise airflow control and high efficiency.

Model types and design

The Y6-30 series centrifugal fan includes seven different machine sizes: No. 3.5C, 4.3C, 4.8C, 5.4C, 6.5C, 7.5C, and 8.6C.

  1. 1. This industrial blower is available in both right-hand and left-hand designs. The fan's rotation direction is defined by how the impeller turns when viewed from the motor’s end. Clockwise rotation is termed as "right-hand," while counterclockwise rotation is identified as "left-hand".
  2. 2. The fan’s outlet direction is determined by the casing angle, with both left and right-hand versions offering multiple options (0°, 45°, 90°, 135°, 180°, 225°) to suit specific airflow needs. Customers are advised to specify the rotation direction and outlet angle when placing orders.
  3. 3. The fan is available in two transmission types: C type and D type.

Rotation and outlet positioning

This centrifugal blower can rotate in both clockwise and counterclockwise directions. The right-hand or left-hand orientation is defined by how the impeller moves when viewed from the motor’s side. The fan’s outlet can be adjusted to several angles to optimize airflow, with options such as 45°, 90°, 135°, and more.

 

Structure and components

The Y6-30 centrifugal fan is constructed from five major parts: impeller, casing, air damper, transmission, and air inlet.
① The impeller consists of multiple blades and a robust design made from steel plates. The entire impeller assembly is dynamically balanced to ensure efficient performance, low noise, and smooth operations.
② The casing is a durable spiral structure, fully welded from steel plates.
③ An adjustable air damper is included with most Y6-30 industrial centrifugal fans, allowing for control of air volume and pressure as required by the boiler’s operation.
④ The transmission system consists of a high-quality main shaft made from top-grade steel, housed within a bearing box. The bearings are of rolling type, and the bearing box has ample space for cooling oil, along with an oil level indicator for smooth functioning.

Performance and selection criteria

  • The performance of this high-pressure centrifugal fan is measured in terms of airflow, total pressure, speed, shaft power, and overall efficiency. The data provided in the performance charts assumes a working temperature of 200°C, atmospheric pressure of 101300Pa, and a flue gas density of 0.745kg/m³. Any variations in these conditions should be accounted for through formula-based adjustments. The motor’s power capacity typically includes a safety factor of 1.3.
  • Fan selection
    ① The Y6-30 centrifugal blower is designed for optimal performance when used with industrial boilers. Fan selection can be made by referring to the performance charts. In cases where the boiler's output changes, adjustments should be made based on airflow and resistance.
    ② For non-boiler applications, consult the performance data and adjust accordingly.
    ③ The blower is typically equipped with a flow regulation device at the air inlet (or utilize the boiler's built-in regulating valve) to fine-tune air pressure and volume for specific needs.
(Rotation Speed 2350 r/min, Altitude 0 km, Fan Inlet Temperature 200°C, Fan Inlet Gas Density 0.743 kg/m³, Outlet Equivalent Area 0.128)
Flow Rate/(m³/h) Pressure/Pa Static Pressure/Pa Power /kW Compatible Boiler/(t/h) Speed Ratio
Y6-30-12No.3.50C②
655
745
834
923
1000
1103
1192
853
843
834
824
800
765
727
803
778
753
725
683
623
561
0.75   0.2  24.6
26.4
28.2
29.9
31.8
34.6
37.3
Y6-30-15No.3.50C②
622
708
792
877
950
1048
1132
746
738
730
721
700
669
636
701
 680
 657
 631
 595
 541
 487
0.75  0.2  26.5
28.5
30.3
32.2
34.3
37.3
40.2
Y6-30-16No.3.50C②
694
790
884
978
1060
1169
1263
992
981
970
959
931
890
846
936
908
879
847
800
731
660
0.75  0.2  22.6
24.3
25.9
27.5
29.3
31.8
34.3
Y6-30-12 No.4.30C②
1169
1328
1487
1700
1806
1966
2125
1206
1197
1176
1140
1118
1078
1020
1136
1107
1063
992
951
880
789
1.5  0.2  24.3
26.1
28.0
30.6
32.0
34.3
37.2
Y6-30-15 No.4.30C②
11l1
1262
1413
1615
1716
1868
2019
1055
1047
1029
998
978
943
893
992
965
927
865
827
764
684
1.5  0.2  26.1
28.1
30.1
33.0
34.5
37.0
40.1
Y6-30-16 No.4.30C②
1239
1408
1576
1802
1914
2084
2252
1403
1393
1368
1326
1301
1254
1187
1324
1292
1241
1160
1114
1032
927
2.2  0.2 22.4
24.0
25.7
28.1
29.4
31.6
34.2
Y6-30-12 No.4.80C②
1619
1840
2060
2300
2502
2723
2944
1490
1470
1450
1420
1392
1333
1265
1404
1358
1310
1246
1186
1089
979
2.2  0.5  24.3
26.2
28.0
30.1
31.8
34.3
37.1
Y6-30-15 No.4.80C②
1538
1748
1957
2185
2377
2587
2797
1304
1286
1269
1243
1218
1166
1107
1226
1185
1143
1086
1032
945
849
1.5


2.2
0.2


0.5
26.2
28.2
30.2
32.4
34.3
37.0
40.0
Y6-30-16 No.4.80C②
1716
1950
2184
2438
2652
2886
3121
1734
1710
1687
1652
1620
1551
1472
1637
1585
1530
1456
1388
1276
1151
0.5  22.4
24.1
25.7
27.6
29.2
31.5
34.1
① The reference distance refers to the distance from the noise level measurement point to the center of the opening. When the impeller diameter is ≤1m, the reference distance is 1m; when the impeller diameter is >1m, the reference distance is the impeller diameter. The same applies hereafter.
② When the motor power is less than or exceeds the power required by the fan, a new selection must be made. The same applies hereafter.

Y6-30 Industrial Boiler High-Pressure Centrifugal Blower Fan
Y6-30 Industrial Boiler High-Pressure Centrifugal Blower Fan
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.