Y6-11, Y10-11 Centrifugal Induced Draft Fans

Y6-11 and Y10-11 centrifugal induced draft fans are designed for industrial boilers with capacities of 6t/h and 10t/h, handling flue gases up to 250°C. These low-noise fans are optimized for coal-fired boilers with dust removal systems. Their robust structure and flexible air outlet options make them ideal for various industrial applications. Incorporating centrifugal fan, centrifugal blower, and industrial centrifugal fan technologies ensures long-term, reliable operation.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
Y6-11, Y10-11 Centrifugal Induced Draft Fans

Application

Y6-11 and Y10-11 centrifugal fans are a new type of low-noise boiler induced draft fan, suitable for 6t/h and 10t/h industrial boilers with medium temperature not exceeding 250℃, burning various coal qualities and equipped with smoke and dust removal devices. They are ideal new fans; they can also be used in other similar occasions.

Form

1. This fan is a single suction type. Looking at the impeller from one end of the motor, if it rotates clockwise, it is called a right-hand fan, indicated by "right"; if it rotates counterclockwise, it is called a left-hand fan, indicated by "left".
2. The air outlet position of the fan is expressed by the air outlet angle of the casing, which can be made into 7 forms: 0°, 45°, 90°, 135°, 180°, 225°, and 270°.
3. The transmission mode of this fan is D-type transmission, using elastic sleeve pin coupling.

 

Structural characteristics

The fan is mainly composed of an impeller, a casing, an air inlet, an adjusting door, and a transmission part.

  1. 1. The impeller is welded with 12 backward blades, a curved front disc, and a flat rear disc. The impeller is calibrated for static and dynamic balance.
  2. 2. The casing is a volute-shaped structure welded from ordinary steel plates.
  3. 3. The air inlet adopts a convergent-divergent type air inlet and is fixed on the inlet side of the fan by bolts.
  4. 4. The regulating door is a device used to adjust the fan flow. It is installed in front of the air inlet and has an adjustment range from 0° (fully open) to 90° (fully closed). The lever of the regulating door is on the right side when viewed from the inlet. For a right-handed fan, pushing the lever from bottom to top will change it from fully closed to fully open; for a left-handed fan, pulling the lever from top to bottom will change it from fully closed to fully open.
  5. 5. This fan uses rolling bearings and integral bearing boxes. The bearing box is equipped with a thermometer and an oil level indicator. The lubricating oil is L-AN46, a full-loss system oil, and the amount of oil added is in accordance with the requirements of the oil level mark. If grease is used, an oil baffle should be added on the side of the ball in the bearing box, and its fixing groove has been prefabricated. This fan is equipped with a water cooling device, so a water pipe must be installed. The water consumption depends on the temperature and is generally considered to be 0.5 ~ 1m³/h.

 

Performance and selection

The dimensionless performance table is provided for the Y6-11 and Y10-11 fans. The dimensionless performance table is used to calculate the dimensional performance of other models. When the actual use status does not match the standard status, the performance of the actual use status must be converted to the performance of the standard status, and then the fan is selected based on the converted performance.
Rotating Speed/(r/min) Air Flow /(m³/h) Pressure /Pa Power /kW
1450  13848  3175  30 
15862  3185 
17625  3146 
18883  3106 
21150  2999 
23164  2852 
24423  2744 
25682  2597 
20390  4135  40/55

55
23356  4037 
25951  3920 
27804  3822 
31141  3597 
34107  3263  75 
35960  2999 
37814  2685 

Y6-11, Y10-11 Centrifugal Induced Draft Fans
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch
Category
Get in Touch