• China Office Hotline
    0086 533 5201284
  • Vietnam Hotline
    0084 086 9378260
  • Singapore Hotline
    0065 3163 2969
  • Free Consultancy
    info@decent-machinery.com

Y5-48 Industrial Centrifugal Blower for Boiler Smoke Removal

The Y5-48 centrifugal induced draft fan is engineered for industrial boilers with capacities from 1 to 20t/h. This high-performance fan operates at temperatures up to 250°C and is designed to efficiently handle smoke and dust extraction. Ideal for various coal-fired boilers, it features adjustable outlet angles and robust construction to ensure reliable operation and extended service life.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
Y5-48 Industrial Centrifugal Blower for Boiler Smoke Removal

Application

The Y5-48 centrifugal fan is developed to support industrial boilers with capacities ranging from 1 to 20t/h. It is especially effective in systems that burn different coal types and require smoke and dust removal. The fan is capable of operating under air intake conditions where temperatures do not exceed 250°C. To maximize the longevity and efficiency of the fan, it is recommended to install a dust removal device with a minimum efficiency of 85%, reducing the dust content in the flue gas.

Design and Configuration

The Y5-48 fan adopts a single-suction design and is available in six sizes: No.4, 5, 6.3, 8, 10, and 12.5. This model can be configured for either clockwise (right-hand) or counterclockwise (left-hand) rotation. The outlet position is highly flexible, with six different angles to choose from: 0°, 45°, 90°, 135°, 180°, and 225°.
 

Key Features

The Y5-48 fan offers several advanced features to meet the needs of various industrial applications:

  1. 1. Impeller: The impeller is constructed with 12 backward-inclined blades, made from durable Q345 (16Mn) steel, ensuring high strength and smooth operation through careful dynamic balancing.
  2. 2. Casing: The volute casing is made from high-grade steel plates, designed to facilitate maintenance through a dust cleaning door that ensures the impeller’s aerodynamic efficiency.
  3. 3. Air Inlet: The air inlet is designed as a streamlined, convergent structure, bolted securely to the casing for optimal airflow.
  4. 4. Regulating Door: Equipped with petal-shaped blades, the regulating door allows for precise control of airflow, with 9 blades for smaller models and 11 blades for larger ones. The external transmission design enhances ease of operation, supported by high-temperature grease for reliable lubrication.
  5. 5. Transmission System: The fan’s transmission system includes a water-cooled bearing setup, made from high-quality steel, with integrated monitoring tools like a thermometer and oil level indicator for maintaining proper lubrication and performance.

Performance and Selection

The Y5-48 fan’s performance is specified in detailed dimensionless tables and curves, reflecting its efficiency in different conditions, such as operating under atmospheric pressure and varying flue gas temperatures. Users can adapt the fan’s performance based on specific operational needs, ensuring it meets the required air volume and pressure for their application.
No. Rotating Speed /(r/min) Pressure /Pa Air Flow /(m³/h) Power /kW
4C 3550  2932
3374
3807
4254
4686
5143
5564
2221
2254
2173
2068
1914
1726
1501
5.5 
3150  2602
2993
3378
3775
4158
4563
4937
1746
1772
1708
1626
1505
1357
1180
4
2800  2313
2661
3003
3355
3696
4056
4388
1377
1398
1348
1283
1188
1071
932
3
2500  2065
2376
2681
2996
3300
3622
3918
1097
1113
1073
1022
946
853
742
2.2 
5C 3150  5304
6062
6820
7578
8336
9093
9851
2819
2793
2737
2592
2406
2175
1913
11 
2800  4715
5389
6062
6736
7409
8083
8757
2223
2203
2158
2044
1898
1716
1509
7.5 
5C 2500  4210
4811
5413
6014
6616
7217
7818
1769
1753
1718
1627
1511
1366
1202
5.5 
2240  3772
4311
4850
5389
5928
6466
7005
1419
1406
1377
1305
1212
1096
964
6.3C 2800  9432
10779
12126
13474
14821
16169
17516
3545
3513
3441
3259
3025
2733
2403
22 
2500  8421
9624
10827
12030
13233
14436
15639
2819
2793
2737
2592
2406
2175
1913
15 
2240  7546
8623
9701
10779
11857
12935
4013
2259
2238
2193
2077
1929
1743
1533
11 
2000  6737
7700
8662
9624
10586
11549
12511
1798
1781
1745
1654
1535
1388
1221
7.5 

Y5-48 Industrial Centrifugal Blower for Boiler Smoke Removal
Y5-48 Industrial Centrifugal Blower for Boiler Smoke Removal
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch
Category