Y5-47 Type II High-Efficiency Centrifugal Induced Draft Fan for Boilers

The Y5-47 Type II centrifugal induced draft fan is optimized for industrial boilers ranging from 0.2 to 20t/h, ensuring efficient smoke and dust elimination. With a maximum operating temperature of 250°C, this high-pressure centrifugal fan is engineered for superior performance with reduced noise levels. Ideal for various coal qualities, it is equipped with adaptable features for left or right-hand rotation and multiple air outlet angles, making it a versatile choice for demanding industrial applications.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
Y5-47 Type II High-Efficiency Centrifugal Induced Draft Fan for Boilers

Application

The Y5-47 Type II boiler centrifugal induced draft fan is designed for industrial boilers with capacities ranging from 0.2 to 20t/h. It is particularly suitable for applications involving smoke and dust removal, where air inlet conditions require a maximum temperature not exceeding 250°C. This industrial centrifugal fan can accommodate various coal qualities and adapt to different dust collectors and installation pipeline resistances, making it versatile across a wide range of industrial boiler systems.

Type

The Y5-47 Type II fan is an enhanced version of the original Y5-47 fan, featuring improved efficiency and reduced noise levels. It offers full-pressure internal efficiency of 85.6% at optimal operation points, with a noise index of 12.5dB(A). The fan is available in multiple sizes, from No.3.15 to No.11D, with options for both left-hand and right-hand rotation. The fan’s air outlet angles can be customized to 0°, 90°, or 180°, depending on specific application needs. Additionally, the fan offers two transmission modes: Type C (belt drive) and Type D (elastic coupling drive).
 

Structural Features

The Y5-42 centrifugal fan is composed of several key components:

  1. 1. Impeller: The impeller consists of 12 backward-inclined flat blades made from Q345 (16Mn) steel, ensuring high strength, wear resistance, and smooth operation due to dynamic balancing.
  2. 2. Casing: The volute casing is constructed from welded steel plates and is compatible with both left-hand and right-hand rotations for machines above No.8.
  3. 3. Transmission: The main shaft is made from high-quality steel, supported by ball bearings, with options for low-noise bearings on smaller models. The transmission is either belt-driven (Type C) or directly driven via elastic coupling (Type D).
  4. 4. Air Inlet: The convergent-divergent air inlet is integrated into the casing and fixed with bolts for secure attachment.
  5. 5. Regulating Door: The fan features adjustable regulating doors, with a three-blade design for smaller models and an eleven-blade design for larger models, allowing precise control of airflow.

Performance and Selection

Performance parameters, including flow rate and total pressure, are detailed in the performance and options table, allowing for precise selection based on specific application requirements. The fan’s efficiency is divided into 8 performance points within the range of 90% maximum efficiency. For accurate performance adjustments, users should refer to the fan selection curve and performance table, considering the specific operating conditions, such as gas temperature and atmospheric pressure.
No.3.15C
Rotating Speed /(r/min) Pressure /Pa Air Flow /(m³/h) 功率/kW
3250  1049
1040
1020
990
941
873
794
716
1323
1489
1654
1820
2000
2166
2331
2496
1.5
2990  883
883
883
843
794
735
657
608
1218
1370
1522
1674
1840
1992
2144
2297
1.5 
2750  745
745
726
706
677
628
579
520
1120
1260
1400
1540
1692
1832
1973
2112
1.5 
No.4C
3300  1922
1912
1873
1853
1795
1706
1559
1393
2751
3095
3439
3783
4158
4502
4846
5190
2900  1481
1481
1442
1432
1383
1324
1206
1079
2417
2720
3022
3325
3654
3957
4259
4561
5C
2900  2324
2314
2256
2236
2167
2060
1893
1687
4723
5313
5903
6494
7138
7728
8318
8909
7.5 
2620  1893
1883
1844
1824
1775
1687
1540
1373
4267
4800
5333
5867
6448
6982
7515
8048
5.5 

Y5-47 Type II High-Efficiency Centrifugal Induced Draft Fan for Boilers
Y5-47 Type II High-Efficiency Centrifugal Induced Draft Fan for Boilers
Y5-47 Type II High-Efficiency Centrifugal Induced Draft Fan for Boilers
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.