The Y10-21, Y10-24, and Y8-24 high-efficiency, low-noise induced draft fans are designed for industrial boilers (1t/h, 2t/h, 4t/h) equipped with smoke and dust removal devices. These Industrial Centrifugal Fans ensure reliable performance under temperatures up to 250°C. With right-hand and left-hand configurations, these High-Pressure Centrifugal Fans offer efficient air intake and longer service life due to reduced dust content in the flue gas.



Y10-21, Y10-24, Y8-24 high-efficiency and low-noise induced draft fans are designed to match industrial boilers (1t/h, 2t/h, 4t/h) that burn various coal qualities and are equipped with smoke and dust removal devices; they can be used with comparable air intake conditions and comparable performance. The maximum temperature shall not exceed 250℃. A dust removal device with an efficiency of not less than 85% must be installed in front of the induced draft fan to reduce the dust content of the smoke entering the fan, so as to increase the life of the fan.
Two types of drive are equipped for induced draft fans of different tonnages: D type (direct connection) and C type (belt drive). Among them, Y8-24 and Y10-21 are D or C type drives, and Y10-24 is C type drive. The D type drive has a slightly larger machine number, a lower speed (n=1450r/min), and better wear resistance; the C type drive has a slightly smaller machine number and a slightly higher speed (n=1750~2100r/min), but both achieve the required pressure head at the minimum linear speed to reduce noise and wear resistance. This fan has low noise, ensuring that it is less than 85dB within the operating conditions. Using some analysis results of two-phase flow, wear resistance is considered from the flow channel shape. Various induced draft fans with different requirements can be selected from this group. The fan consists of an impeller, a casing, an air inlet, a transmission part, an integral bracket, etc.
| 1t/h Industrial Boiler Centrifugal Fan | ||||
| Rotating Speed (r/min) | Full Pressure /Pa | Air Flow /(m³/h) | Motor | |
| Model | Power /kW | |||
| 2000 |
1412 1482 1553 1592 1585 1592 |
1936 2406 2879 3349 3823 4293 |
Y112M-4 | 4 |
| 2240 |
1581 1659 1739 1783 1775 1783 |
2168 2694 3225 3751 4282 4808 |
Y132S4 | 5.5 |
| 2500 |
1765 1852 1941 |
2419 3007 3599 |
Y132S-4 | 5.5 |
|
1990 1981 1990 |
4187 4779 5367 |
Y132M-4 | 7.5 | |
| Note: Inlet Air Condition: Pa=101300Pa, t=250°C,p=0.674kg/m³ . | ||||
















|
|
|
|
| Decent Fan Customer Comment | Impellers Dynamic and Static Balance Test | Centrifugal Fan Factory Tour |
|
|
|
|
| Complete Centrifugal Fan Assembly Guide | Centrifugal Fan Laboratory Testing | High-Performance Centrifugal Fan Unveiled |
|
|
|
|
| Silent and Powerful Centrifugal Fan | Advanced Centrifugal Fan Manufacturing Process | Decent Machinery Fan Production Revealed |