L9-10 Series High-Pressure Cooling Centrifugal Fan for Power Plant Fire Detection

The L9-10 Series High-Pressure Centrifugal Fans are specially developed for cooling applications in fire detection systems for power plant boilers. These industrial fans are compact, lightweight, and easy to maintain, providing reliable and efficient performance. They are suitable for handling non-corrosive, non-spontaneous combustion, and non-sticky gases at temperatures up to 80℃. Additionally, the L9-10 Centrifugal Fan can be an effective alternative to Roots blowers for specific usage scenarios.

  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
L9-10 Series High-Pressure Cooling Centrifugal Fan for Power Plant Fire Detection

Application


The L9-10 Series Centrifugal Fans are designed to deliver high-pressure cooling air for fire detection systems in power plants. These fans are suitable for non-corrosive, non-spontaneous combustion, and non-sticky gases with a maximum medium temperature of 80℃ and a dust concentration below 150 mg/m³. They provide reliable cooling performance for industrial applications, ensuring safety and stability under high-temperature conditions.
 

Structural Characteristics


The L9-10 Centrifugal Fan is constructed with a uniquely designed impeller that features long and short blades, welded between a specially shaped front and rear cover. The housing and transmission part are integrated into a single welded frame, providing a compact structure, reduced weight, and easy maintenance. The inlet is equipped with a filter to prevent dust ingress, while the outlet has a soft connection to minimize vibration. An optional vibration absorber can be configured to isolate the vibration source according to user requirements. The L9-10 Centrifugal Fan can replace Roots blowers in certain scenarios, offering enhanced performance and reliability.

Performance and Selection


  1. 1. Before starting, manually rotate the coupling to ensure that there is no friction between the moving parts and fixed components.
  2. 2. Close the regulating device before startup. Once the fan reaches normal operation, gradually open the regulating device to reach the desired pressure. Starting with the regulating device fully open may cause motor damage.
  3. 3. If the ambient temperature exceeds 40°C, connect a water cooling pipe to avoid overheating during operation.
  4. 4. For regular maintenance, replace the bearing lubrication with MoO₂ grease every three months to ensure the fan operates smoothly and extends its service life.

The L9-10 Series High-Pressure Centrifugal Fans are ideal for various industrial cooling applications, particularly for power plant boiler fire detection systems. With multiple features to enhance safety and efficiency, these fans provide a robust solution for high-temperature environments.

Rotating Speed /(r/min) Full Pressure /Pa Air Flow /(m³/h) Motor Power /kW
2900  11215  987  22 
11694  1270 
11870  1556 
12017  1850 
12106  2138 
11968  2403 
11772  2718 
11478  3006 
Note: The above performance is based on p = 1.2 kg/m³ and pa = 101303 Pa (calculated under standard conditions).
L9-10 Series High-Pressure Cooling Centrifugal Fan for Power Plant Fire Detection
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch
Category
Get in Touch