The NTGY-11 Series Boiler Centrifugal Induced Draft Fan is engineered specifically for use in 10-220t/h circulating fluidized bed boilers and conventional boilers (10-120t/h) in regions with low atmospheric pressure, including western China. This industrial centrifugal fan series is optimized for high performance, supporting air intake conditions up to 250°C and minimizing dust content through compatible dust collectors, achieving over 85% efficiency in flue gas treatment.
| NTGY-11No.11.5D、No.12D | |||||
| Model | Rotating Speed /(r/min) | Air Flow /(m³/h) | Pressure /Pa | Motor | |
| No. | Power /kW | ||||
| 11.5D | 1450 | 17127 | 3691 | 55 | |
| 24634 | 3755 | ||||
| 28969 | 3547 | Y250M-4 | |||
| 31561 | 3405 | ||||
| 34149 | 3262 | ||||
| 37193 | 3066 | ||||
| 40560 | 2805 | Y280S-4 | 75 | ||
| 42149 | 2673 | ||||
| 12D | 1450 | 18028 | 3728 | Y250M-4 | 55 |
| 2593 | 3793 | ||||
| 30494 | 3583 | ||||
| 33222 | 3439 | ||||
| 35946 | 3295 | Y280S-4 | 75 | ||
| 39151 | 3097 | ||||
| 42695 | 2833 | ||||
| 4436 | 2700 | ||||
| NTGY-11No.12.5D、No.14D | |||||
| Model | Rotating Speed /(r/min) | Air Flow /(m³/h) | Pressure /Pa | Motor | |
| No. | Power /kW | ||||
| 2.5D | 1450 | 20377 | 4045 | Y280S-4 | 75 |
| 29309 | 4116 | ||||
| 34467 | 3888 | ||||
| 37550 | 3732 | ||||
| 40629 | 3575 | ||||
| 44252 | 3360 | ||||
| 48257 | 3074 | ||||
| 5014 | 2930 | ||||
| 14D | 1450 | 28628 | 5074 | Y315S-4 | 110 |
| 41177 | 5163 | ||||
| 48423 | 487 | ||||
| 52755 | 4681 | Y315M-4 | 132 | ||
| 5708 | 4485 | ||||
| 62170 | 4215 | ||||
| 67798 | 3856 | ||||
| 70453 | 3675 | ||||
| NTGY-11No.19D、No.20D | |||||
| Model | Rotating Speed /(r/min) | Air Flow /(m³/h) | Pressure /Pa | Motor | |
| No. | Power /kW | ||||
| 19D | 960 | 53837 | 4990 | Y355L-6 | 220 |
| 77430 | 5076 | ||||
| 91054 | 4794 | ||||
| 99197 | 4603 | ||||
| 107334 | 4410 | ||||
| 116902 | 4145 | Y355L-6 | 250 | ||
| 127485 | 3791 | ||||
| 13247 | 3613 | ||||
| 20D | 960 | 62793 | 5529 | Y355L2-6 | 280 |
| 90310 | 5624 | ||||
| 106201 | 5312 | ||||
| 15699 | 5100 | ||||
| 25189 | 4886 |
Y400-6 6kV |
315 | ||
| 136349 | 4593 | ||||
| 148692 | 4201 | ||||
| 154515 | 4003 |