The GG2-1 to GG6-1 and GY2-1 to GY6-1 centrifugal and induced draft fans are designed for use with 2t/h, 4t/h, and 6t/h industrial boilers. These fans offer superior air volume and pressure control, enhancing the efficiency of smoke and dust removal processes. Equipped with energy-saving two-speed motors, they ensure optimal performance across varying boiler loads, reducing energy consumption.



The GG2-1 to GG6-1 and GY2-1 to GY6-1 series centrifugal fans are ideal for supporting 2t/h, 4t/h, and 6t/h industrial boilers. With considerations for different types of boilers, fuel quality, and system resistances (such as dust collectors and economizers), these fans provide consistent air pressure and volume for reliable performance. The fans’ key characteristics include a high-efficiency zone and flat performance curve, making them well-suited for smoke and dust extraction, contributing to a cleaner environment. Their two-speed motor allows for adjustments to fit various operational demands, providing significant energy savings. For optimal performance, it is necessary to install a dust filtration system to ensure that the dust content entering the fan remains low, with an efficiency rating of at least 85%.
The structure of these fans includes an impeller, housing, air inlet, bracket, transmission part, and adjustment mechanism:
The performance of the fans, including parameters such as air volume, total pressure, shaft speed, and efficiency, is based on standard operating conditions (air at 20°C and 101325 Pa). For induced draft fans, performance is calculated with a flue gas temperature of 200°C. The performance tables reflect operation with the adjustment mechanism fully open at 0°. If your operating conditions differ, performance should be recalculated accordingly.
| Rotating Speed /(r/min) | Full Pressure /Pa | Air Flow /(m³/h) | Fan Power (with 30% Margin)/kW | Motor | |||
| Single-speed Motor Model | Power /kW | Dual-speed Motor Model | Power /kW | ||||
| GY2-1 Induced Draft Fan (Inlet Conditions: pa = 1.013×10⁵ Pa, Temperature t = 200°C, Gas Density ρ = 0.745 kg/m³) | |||||||
| 1450 | 2510 | 3000 | 4.1 | Y132M-4 | 7.5 | Y2TY160M-4/8 | 7.5/2.2 |
| 2599 | 4000 | 5.04 | |||||
| 2648 | 5000 | 6.13 | |||||
| 2599 | 6000 | 7.18 | |||||
| △①2550 | 6600 | 7.68 | |||||
| 2500 | 7000 | 8.26 | |||||
| 2432 | 7500 | 8.95 | |||||
| 2305 | 8000 | 9.70 | |||||
| GG4-1 Centrifugal Fan (Inlet Conditions: pa = 1.013×10⁵ Pa, Temperature t = 200°C, Gas Density ρ = 0.745 kg/m³) | |||||||
| 2900 | 2990 | 5000 | 5.9 | Y132S2-2(B35) | 7.5 | Y4TS132M-4/2 | 1.4/7 |
| 2740 | 6000 | 6.25 | |||||
| △①2450 | 7000 | 6.51 | |||||
| 2255 | 8000 | 6.6 | |||||
| 1960 | 9000 | 6.81 | |||||
| 1490 | 10000 | 6.15 | |||||
| 1450 | 3267 | 9500 | 14.72 | Y180M-4 | 18.5 | Y4TY180L-8/4 | 3.4/18.5 |
| 3346 | 10800 | 15.92 | |||||
| △①3325 | 11800 | 17.64 | |||||
| 3315 | 12800 | 18.71 | Y180L-4 | 22 | |||
| 3305 | 13800 | 20.23 | |||||
| 3285 | 14400 | 21.7 | |||||
| 3236 | 15900 | 23 | |||||
| GG6-1 Centrifugal Fan (Inlet Conditions: pa = 1.013×10⁵ Pa, Temperature t = 200°C, Gas Density ρ = 0.745 kg/m³) | |||||||
| 1450 | 2109 | 7000 | 6.21 | Y132M-4 | 7.5 | Y6TS160M-4/6 | 7.5/2.5 |
| 2040 | 8000 | 6.45 | |||||
| △①1961 | 8750 | 6.53 | |||||
| 1030 | 9000 | 6.75 | |||||
| 1844 | 10000 | 7.15 | |||||
| 1648 | 11000 | 7.20 | |||||
| 1442 | 12000 | 7.23 | |||||
| 1450 | 3214 | 14000 | 20.70 | Y200L-4 | 30 | YD225M-4/6 | 27/8.5 |
| 3256 | 16000 | 23.50 | |||||
| △W3187 | 18000 | 26.58 | |||||
| 3070 | 20000 | 29.40 | |||||
| 2922 | 22000 | 32.67 | |||||
| 2824 | 23000 | 34.18 | |||||














|
|
|
|