This specialized centrifugal fan series is crafted for use in circulating fluidized bed and boiling boilers, facilitating effective airflow and gas management. The centrifugal blower supports air up to 80°C, while the induced draft fan accommodates flue gases at temperatures as high as 250°C. Integrating a dust removal system before the induced draft fan optimizes operation by reducing particulate matter, ensuring clean, efficient performance for power plant applications.
These industrial centrifugal fans incorporate an impeller, casing, inlet, regulating door, and transmission system, ensuring reliability and durability for industrial operations.
Flow inconsistencies may occur due to various operational conditions, such as changes in pipe network resistance or variations in fan pressure. To address this:
Flow adjustments can be made by modifying the regulating door’s position, altering fan speed, or selecting a fan with the appropriate pressure level. When the actual airflow is significantly above the desired rate, reducing speed or selecting a fan with a lower pressure rating is more efficient. If the airflow remains insufficient even with the regulating door fully open, reducing pipe resistance or selecting a higher-pressure fan may be required. Standard performance is calculated under atmospheric pressure (pa=101300Pa), at a gas temperature of 175°C, with a gas density of ρ=0.785kg/m³. Performance values should be converted for any deviations from these standard conditions to ensure optimal fan selection.
| Model | Rotating Speed(r/min) | Air Flow(m³/h) | Full Pressure /Pa | Fan Power /kW | Motor |
|
GY6-11 No.11.2D |
1480 | 9234 | 4916 | 21.76 |
Y225S-4 37kW |
| 11389 | 5000 | 26.07 | |||
| 13544 | 4958 | 30.22 | |||
| 15698 | 4830 | 34.33 | |||
| 17853 | 4624 | 38.76 |
Y225M-4 45kW |
||
| 20008 | 4411 | 43.56 | |||
|
GY10-11 No.12.5D |
1480 | 12837 | 6288 | 37.67 |
Y250M-4 55kW |
| 15833 | 6398 | 45.13 | |||
| 18829 | 6343 | 52.32 | |||
| 21823 | 6178 | 59.47 |
Y280S-4 75kW |
||
| 24819 | 5913 | 67.12 | |||
| 27815 | 5640 | 75.41 | |||
|
GY10-12 No.11.2D |
1480 | 24625 | 5278 | 58.02 |
Y280S-4 75kW |
| 27704 | 5203 | 63.73 | |||
| 30781 | 5086 | 69.95 | |||
| 33860 | 4950 | 76.58 |
Y280M-4 90kW |
||
| 36938 | 4776 | 83.49 | |||
| 40016 | 4559 | 89.98 | |||
|
GY15-11 No.12.5D |
1490 | 34465 | 6708 | 102.51 |
Y315M1-4 132kW |
| 38773 | 6612 | 112.58 | |||
| 43082 | 6461 | 123.61 | |||
| 47389 | 6286 | 135.32 |
Y315M2-4 160kW |
||
| 51698 | 6065 | 147.51 | |||
| 56006 | 5788 | 158.72 | |||
|
GG15-11 No.8.6D |
2960 | 10753 | 20051 | 90 |
Y280M-2 90kW |
| 12175 | 20462 | ||||
| 12831 | 20678 | 110 |
Y315S-2 110kW |
||
| 14676 | 20776 | ||||
| 15680 | 20864 | 132 |
Y315M1-2 132kW |
||
| 16973 | 20776 | ||||
| 17718 | 20727 | ||||
| 19078 | 20413 | 160 |
Y315M2-2 160kW |
||
| 20215 | 20051 | ||||
| Noted:Inlet Air Condition pa=101.325kPa, t=20℃, ρ=1.2kg/m³. | |||||














|
|
|
|