High-Performance Induced Draft Fan for Circulating Fluidized Bed Boilers

Engineered for circulating fluidized bed boilers, the Szcgx and Szcyx Series Induced Draft Fans provide consistent and efficient airflow control. Designed for primary and secondary air requirements with temperatures up to 80°C, these fans handle flue gas up to 250°C in induced draft applications, meeting the rigorous standards of power plant environments. Integrated dust reduction improves performance, with removal efficiencies exceeding 85%.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
High-Performance Induced Draft Fan for Circulating Fluidized Bed Boilers

Overview

 

The Szcgx and Szcyx Series Fans deliver high-efficiency ventilation for industrial boiler systems. Designed for circulating fluidized bed boilers in power plant applications, they effectively manage primary and secondary airflows at temperatures up to 80°C, while the induced draft model handles flue gases up to 250°C. A dust collector must be installed to control the dust content in the flue gas, ensuring a minimum 85% dust removal efficiency.


Configuration and Design


  1. 1. Drive Mode: Available in D-type and F-type drives, these fans use elastic coupling for consistent performance.
  2. 2. Air Inlet and Outlet Positioning: The position of each inlet and outlet is specified by the angles on the fan’s casing and air inlet box. For instance, an outlet angle of 45° and inlet angle of 135° is recorded as 45°/135°—specific to F-type configurations with air inlet boxes. For D-type fans, only the outlet angle is indicated.
  3. 3. Rotation Direction: Viewed from the motor end, clockwise rotation indicates a right-hand fan, denoted by "right," while counterclockwise rotation indicates a left-hand fan, denoted by "left."

Structural Features

 

  1. 1. Impeller: Constructed with backward-curved, single-plate blades, the impeller is balanced both statically and dynamically. This design includes wear-resistant components to enhance durability and lifespan, reducing operational disruptions.
  2. 2. Casing: The fan casing is crafted from durable steel plates with options for a fully enclosed or split-type casing, which separates along the centerline. Induced draft models have additional reinforcements to withstand wear.
  3. 3. Air Inlet: The air inlet is designed for efficient flow, featuring a convergent shape that attaches to the casing with secure bolts.
  4. 4. Adjustment Door: Located at the inlet, the adjustment door controls airflow within a range of 0° (fully open) to 90° (fully closed). For right-hand fans, lifting the handle adjusts it from closed to open, while left-hand fans use a downward motion.
  5. 5. Transmission System: Made with high-grade steel, the main shaft operates on rolling bearings within an integrated or pillow-type bearing box, depending on fan size. The bearing boxes are equipped with a thermometer and oil level gauge. Cooling systems include water cooling for D-type fans and circulating oil cooling for F-type fans, utilizing L-AN46 lubrication.

Performance and Selection


The Szcgx and Szcyx Series fans are optimized for efficient airflow within the specified parameters of circulating fluidized bed boiler systems. The performance tables provide parameters adaptable for specific process conditions, allowing for modifications as necessary to achieve peak efficiency.

Rotating Speed /(r/min)   Air Flow /(m³/h) Full Pressure /Pa Fan Power /kW Motor
No. Power/kW
SZCYX35-1No.12D
1450    43770  5286  112  Y315M1-4 132 
  51937  5523  128 
  60082  5538  148  Y315M2-4 160 
  68252  5570  172  Y315L-4 185 
  76414  5212  192  Y315L2-4 200 
  84537  5175  208 
  92734  4876  224  Y355-4 250 
SZCYX35-1No.13D
1450  44331  5088  113  Y315M1-4 132 
55038  5065  130 
65693  4290  146  Y315M2-4 160 
76401  4678  160 
87108  4366  173  Y315L-4 185 
97767  4004  185 
108470  3642  196  Y315L2-4 200 
SZCYX35-1 No.14D
1450  55369  5902  164  Y315-4 185 
68741  5874  188 
82051  5706  211  Y355-4 250 
95423  5427  232 
108796  5063  250 
122109  4644  267  Y355-4 280 
135478  4223  284 
   SZCYX35-1ANo.14D
1450  51835  5673  144  Y315M2-4 160 
58214  5282  144 
64792  5177  152 
71271  5116  160 
78341  4970  169  Y315L-4 185 
84820  4724  176 
91299  4331  180 
97779  3858  184 
SZCYX35-1ANo.16D
960  54720  3379  92.9  Y315M3-6 132 
67936  3362  106.5 
81089  3266  119.4 
94304  3106  131.2 
107520  2898  141.4  Y355M1-6 160 
120678  2658  151.0 
133890  2418  160.5 

High-Performance Induced Draft Fan for Circulating Fluidized Bed Boilers
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.