High-Efficiency 35t/h-220t/h Boiler Fan for Circulating Fluidized Bed Systems

This High-Pressure Boiler Fan series, supporting 35t/h to 220t/h fluidized bed boilers, is optimized for ventilation and air supply needs in industrial applications. The centrifugal fan range includes primary, secondary, and induced draft models, each designed for high performance and low noise levels. With advanced air and flue gas handling capabilities up to 250°C, these industrial centrifugal fans are perfect for power plants requiring robust, energy-efficient airflow solutions.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
High-Efficiency 35t/h-220t/h Boiler Fan for Circulating Fluidized Bed Systems

Application

 

The 35t/h to 220t/h Circulating Fluidized Bed Boiler Fan series, developed to support diverse fuel types, offers a compact and efficient design for industrial settings, especially in power generation. This industrial centrifugal fan series covers primary, secondary, and induced draft fan requirements for efficient air circulation and pressure stability. High-pressure centrifugal fans like these are essential for maintaining airflow in blast and induced draft systems. The primary and secondary fans operate within a maximum air temperature of 80°C, while the induced draft fan can handle flue gas temperatures up to 250°C, with dust content controlled below 200mg/m³.
 

Form


  1. 1. Each primary, secondary, and induced draft fan operates as a single-suction centrifugal blower.
  2. 2. Models include both right-hand (clockwise rotation) and left-hand (counterclockwise rotation) configurations.
  3. 3. The position of air intake and outlet angles is indicated by the casing’s design for efficient setup.
  4. 4. Transmission options include D-type and F-type coupling transmissions, providing stable and efficient power delivery.

Structural Characteristics


This fan series comprises an impeller, casing, air intake, air intake box, regulating door, and transmission system.

  1.  
  2. 1. Impeller: Built with precision-welded curved blades, the impeller is balanced dynamically and statically, with enhanced stability and durability for extended operation. Induced draft fans use backward-inclined blades with protective wear-resistant coatings.
  3. 2. Casing: Formed from steel plates, the spiral casing ensures durability and easy maintenance, with designs that allow full disassembly along the shaft centerline.
  4. 3. Air Intake: Engineered as a streamlined, convergent structure, the air intake minimizes air resistance for optimized airflow.
  5. 4. Regulating Door: This door controls the airflow, adjustable from fully open (0°) to fully closed (90°). It uses specialized lubricants: calcium-sodium grease for primary/secondary fans, and high-temperature molybdenum disulfide grease for induced draft fans, ensuring smooth and responsive adjustments.
  6. 5. Transmission: Consisting of a high-quality steel shaft, rolling bearings, and optional water-cooling for optimal temperature regulation (0.5-1m³/h water usage based on temperature). An oil level indicator and thermometer support maintenance requirements.

Performance and Selection


The fan series operates within specified performance parameters ideal for fluidized bed boilers, yet can be adjusted to align with custom requirements. Performance assessments are conducted under standard conditions, with recalculations to match the operational conditions of each installation. This ensures high-pressure centrifugal fans in this series meet the rigorous demands of power plants, delivering stable, energy-efficient air movement.

Rotating Speed /(r/min) Air Flow /(m³/h) Full Pressure /Pa Fan Power /kW Motor Power /kW
SFGX35-4A No.7D
2600 11529 6063 32 45
12970 16 34
14411 5905 36
15853 5856 38
17424 565 39
18865 5398 42
20307 4923 42
21747 4432 43
SFGX35-2 No.9D
1450 12519 5011 25.72 30
14084 4945 28.25
15649 4825 30.95
17214 4678 33.81 45
18779 450] 36.78
20344 4295 39.66
21909 4080 42.46
Note: Inlet conditions: atmospheric pressure Pa=101325Pa, gas temperature t=20℃ , gas density ρ=1.2kg/m³
SFYX35-1 No.12D
1450 43770 5286 112 132
51937 5523 128
60082 5538 148 160
68252 5570 172 185
76414 5212 192 200
84537 5175 208
92734 4876 224 250
Note: Inlet conditions: atmospheric pressure Pa=101325Pa, gas temperature t=150℃ , gas density ρ=0.83kg/m³
SFGX35-1A No.12.5D
1450 13207 9228 51.9 75
16289 9385 62.3
19370 9336 72.3
22452 9120 82.4 110
25533 8855 93.9
28615 8532 106.7
31696 8208 121.2 132
Note: Inlet conditions: atmospheric pressure Pa=101325Pa, gas temperature t=200℃ , gas density ρ=1.2kg/m³
SFYX35-1 No.13D
1450 44331 5088 113 132
55038 5065 130
65693 4290 146 160
76401 4678 160
87108 4366 173 185
9776 4002 185
108470 3642 196 200

High-Efficiency 35t/h-220t/h Boiler Fan for Circulating Fluidized Bed Systems
High-Efficiency 35t/h-220t/h Boiler Fan for Circulating Fluidized Bed Systems
High-Efficiency 35t/h-220t/h Boiler Fan for Circulating Fluidized Bed Systems
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.