G6-41, Y6-41 High-Pressure Boiler Induced Draft Fan

The G6-41 and Y6-41 series high-pressure centrifugal fans are ideal for use in industrial boiler systems. These induced draft fans are specifically designed for boilers with evaporation capacities between 0.5 and 10 t/h, ensuring efficient and quiet airflow management. With a durable steel construction, they are available in both right-hand and left-hand configurations, offering flexibility for various industrial applications.

  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
G6-41, Y6-41 High-Pressure Boiler Induced Draft Fan

Application

The G6-41 and Y6-41 series centrifugal blowers are designed to support various industrial boiler systems with capacities ranging from 0.5 to 10 t/h. These induced draft fans provide highly efficient and quiet airflow for boiler applications, offering reliable performance across a wide range of boiler configurations.

Boiler Capacity (t/h) Induced Draft Fan Forced Draft Fan
0.5 Y6-41-11 No.3.55C G6-41-1 No.2.5A
1 Y6-41-11 No.4.5C G6-41-1 No.3.3A
2 Y6-41-11 No.5.4C G6-41-1 No.5.4A
4 Y6-41-11 No.7.1C G6-41-1 No.6.4A
6 Y6-41-11 No.9-10C G6-41-1 No.7.1A
10 Y6-41-11 No.11.2D G6-41-1 No.8.5A

Design Options

These centrifugal fans come in both right-hand and left-hand designs. When viewed from the transmission shaft, right-hand fans rotate clockwise, while left-hand fans rotate counterclockwise. The outlet angles for these fans are available in 0°, 90°, 180°, and 270°, and custom angles can be provided if needed. The G6-41 and Y6-41 series fans can be configured with A or D transmission modes for boiler fans and C or D modes for induced draft fans.
G6-41, Y6-41 High-Pressure Boiler Induced Draft Fan


Structural Features

  • 1. Impeller – The impeller is made with backward-inclined blades and is welded between a conical cover and a flat wheel disc, ensuring stability. The impeller is dynamically balanced to achieve smooth operation, low noise, and high efficiency.
  • 2. Casing – The volute-shaped casing is constructed from high-grade steel plates, ensuring both durability and stable performance. It can be assembled separately or welded directly to the support.
  • 3. Air Inlet – Designed as a converging streamlined structure, the air inlet is bolted to the side of the fan, ensuring minimal airflow loss and efficient gas flow.
  • 4. Transmission System – The transmission system includes a main shaft, bearing box, and either a pulley or coupling. The system is lubricated with L-AN32 oil, which ensures good sealing and a long operational life.
G6-41, Y6-41 High-Pressure Boiler Induced Draft Fan

Performance and Selection

  • 1. Performance Specifications – The G6-41 and Y6-41 boiler fans should be selected based on the required airflow and pressure. Refer to the technical parameters provided for typical operating conditions, and adjust based on specific industrial needs if necessary.
  • 2. Dimensional Performance Conversion – For specific applications, use the dimensionless performance curve for the G6-41 and Y6-41 series fans as a reference. The following formula helps convert these curves into dimensional parameters:
  • G6-41, Y6-41 High-Pressure Boiler Induced Draft Fan
  • Where:

    • pp= total pressure (Pa)
    • ψ\psi= total pressure coefficient
    • ρ\rho= gas density (kg/m³)
    • u2u_2 = circumferential speed (m/s)
    • qvq_v = flow rate (m³/s)
    • ϕ\phi= flow coefficient
    • D2D_2 = impeller outer diameter (m)
    • PP= effective power (kW)
    • λ\lambda= power coefficient
No. Rotating Speed /(r/min) Pressure /Pa Air Flow /(m³/h) Working Condition Moter Power /kW
2.5A 2800  451
589
787
941
1067
1104
1155
1043
953
866
792
652
563
403
Pressure: 940Pa
Air Flow: 800m³/h
0.55 
3.3A 2825  954
1064
1251
1410
1574
1704
1825
1936
2301
2161
2019
1840
1660
1508
1308
1090
Pressure: 1370Pa
Air Flow: 1850m³/h
1.1 
5.4A 1420  994
1044
1114
1166
1207
1237
1254
1254
4358
4040
3722
3403
3085
2767
2448
2130
Pressure: 1176Pa
Air Flow: 3600m³/h
6.4A 1440  1436
1508
1610
1685
1743
1787
1811
1811
7358
6820
6283
5746
5208
4671
4134
3596
Pressure: 1568Pa
Air Flow: 6000m³/h
5.5 
7.1A 1400  1697
1842
2002
2062
2155
2211
2259
2270
10354
9639
8924
8209
7494
6779
6064
5349
Pressure: 1910Pa
Air Flow: 8100m³/h
7.5 
8.5A 1470  2535
2752
2991
3080
3219
3302
3374
3391
18137
16884
15631
14378
13127
11874
10621
9369
Pressure: 3050Pa
Air Flow: 14500m³/h
18.5 

G6-41, Y6-41 High-Pressure Boiler Induced Draft Fan
G6-41, Y6-41 High-Pressure Boiler Induced Draft Fan
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch