The G6-30 and G5-47 Centrifugal Blowers are specifically designed for industrial boiler systems, offering high-performance airflow control with low noise. These centrifugal fans can also be used in air supply and exhaust setups, handling temperatures up to 50°C. Built from high-quality steel, these industrial centrifugal blowers are ideal for ensuring efficient airflow management in various environments.



The blower comprises several key parts: impeller, casing, air inlet, air damper, and a supporting frame.
The performance of the G6-30 and G5-47 fans is measured by airflow rate, total pressure, shaft speed, power consumption, and efficiency. The provided performance data reflects standard operating conditions, with atmospheric pressure at 101325Pa, ambient temperature at 20°C, relative humidity at 50%, and gas density of 1.2kg/m³. If operating conditions differ, performance can be adjusted using applicable formulas. Motor power should always match or exceed the blower’s power requirements for optimal performance.
| Motor Power (kW) | Capacity Safety Factor (K) | Motor Power (kW) | Capacity Safety Factor (K) |
| <0.5 | 1.50 | >2~5 | 1.20 |
| >0.5~1 | 1.40 | >5 | 1.15 |
| >1~2 | 1.30 |
When selecting a centrifugal blower, consider the differences between actual pipe network losses and calculated values, along with any variations in total pressure to ensure proper selection and efficiency.
| Model | No. | Rotating Speed /(r/min) | Full Pressure /Pa | Air Flow /(m³/h) | Power /kW | Compatible Boiler /(t/h) |
| G6-30 | 2.8A | 2900 | 1235 | 563 | 0.75 | 0.2 |
| 1216 | 640 | |||||
| 1206 | 708 | |||||
| 1187 | 794 | |||||
| 1138 | 870 | |||||
| 1098 | 948 | |||||
| 1040 | 1024 | |||||
| G6-30 | 3.5A | 2900 | 1550 | 1217 | 1.1 | 0.5 |
| 1412 | 1346 | |||||
| 1334 | 1406 | |||||
| 1236 | 1465 | |||||
| 1177 | 1501 | |||||
| 1118 | 1572 | |||||
| 971 | 1641 | |||||
| G6-30 | 4.3A | 1450 | 814 | 747 | 0.55 | 0.5 |
| 804 | 874 | |||||
| 785 | 1001 | |||||
| 755 | 1128 | |||||
| 706 | 1255 | |||||
| 657 | 1382 | |||||
| 598 | 1509 | |||||
| G6-30 | 5.4A | 1450 | 1295 | 1602 | 1.1 | 1 |
| 1265 | 1790 | |||||
| 1255 | 1915 | |||||
| 1216 | 2055 | |||||
| 1177 | 2188 | |||||
| 1000 | 2305 | |||||
| 863 | 2505 | |||||
| G5-47 | 4.3A | 1450 | 883 | 1172 | 1.1 | 1 |
| 834 | 1411 | |||||
| 785 | 1785 | |||||
| 736 | 2067 | |||||
| 696 | 2534 | |||||
| 667 | 3011 | |||||
| 588 | 3210 | |||||
| G5-47 | 5A | 1450 | 1128 | 1898 | 1.5 | 2 |
| 1089 | 2699 | |||||
| 1020 | 3318 | |||||
| 961 | 3841 | |||||
| 902 | 4353 | |||||
| 775 | 4911 | |||||
| 686 | 5053 |














|
|
|
|