G5-51-1, Y5-51-1 F-Type Boiler Centrifugal Fan

The G5-51-1, Y5-51-1 F-type boiler centrifugal fans are specifically designed for thermal power plants. They efficiently handle air up to 80°C and flue gases up to 250°C. Available in 14 machine numbers, these high-pressure centrifugal fans are built for single-suction operation, with options for right-hand and left-hand rotation. The robust F-type double-support transmission ensures reliable performance for boiler systems.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
G5-51-1, Y5-51-1 F-Type Boiler Centrifugal Fan

Application

The G5-51-1 and Y5-51-1 F-type boiler draft and induced draft fans are specifically designed for use in thermal power plants. These fans transport air at a maximum temperature of 80°C and handle flue gases up to 250°C, ensuring reliable performance in industrial settings.

Structural Characteristics

  • Machine number.
    The fan and induced draft fan are single-suction types, available in 14 machine numbers ranging from No.8 to No.31.5.

  • Rotation angle.
    Fans can be configured for either right-hand or left-hand rotation. From the motor end, clockwise rotation indicates right-hand, while counterclockwise indicates left-hand.

 

Key Features

The fan consists of an impeller, casing, air inlet, regulating door, and transmission components.
  1. ① The impeller is made from backward-inclined blades welded between a conical front disk and a flat rear disk.
  2. ② The casing is constructed from standard steel plates and welded into a volute structure.
  3. ③ The air inlet is a streamlined, convergent design, securely bolted to the front cover assembly.
  4. ④ The transmission system includes a main shaft, bearing box, and coupling. The high-quality steel shaft is supported by a bearing box with ball bearings. The transmission uses an F-type double-support structure for increased durability.

 

Rotating Rate/(r/min) Air Flow (m³/h) Pressure /Pa Pressure /Pa Moter
G5-51-1No.8.0F
1450
1450
1450
1450
1450
1450
1450
9890
12100
14300
16500
18700
20900
23100
2502
2479
2410
2303
2125
1903
1638
2400
2327
2198
2020
1762
1450
1084
Y160L-4
15kW,380V
Y180M-4
18.5kW,380V
G5-51-1 No.9.0F
1450
1450
1450
1450
1450
1450
1450
14082
17228
20361
23493
26626
29758
32890
3167
3137
3050
2915
2689
2408
2073
3039
2945
2781
2557
2230
1834
1372
Y1800L-4
22kW,380V
Y200L-4
30kW,380V
G5-51-1No.10.0F
1450
1450
1450
1450
1450
1450
1450
19316
23633
27930
32227
36523
40820
45117
3909
3873
3766
3598
3320
2973
2559
3750
3636
3434
3156
2753
2265
1694
Y225M-4
45kW,380V
Y250M-4
55kW,380V
G5-51-1No.11.0F
1450
1450
1450
1450
1450
1450
1450
25710
31455
37174
42894
48613
54332
60051
4730
4687
4556
4354
4018
3.598
3097
4538
4400
4155
3820
3332
2741
2050
Y160L-4
15kW,380V
Y180M-4
18.5kW,380V
G5-51-1No.11.0F
960
960
960
960
960
960
960
17022
20826
24612
28398
32185
35971
39758
2073
2054
1997
1909
1761
1577
1357
1989
1928
1821
1675
1460
1201
898
Y1800L-4
22kW,380V
Y200L-4
30kW,380V
G5-51-1No.12.0F
1450
1450
1450
1450
1450
1450
1450
33379
 40838
 48263
 55688
 63113
 70538
77963
5630
5578
5423
5182
4781
4282
3686
5402
5236
4945
4546
3964
3262
2440
Y225M-4
45kW,380V
Y250M-4
55kW,380V
G5-51-1No.12.0F
960
960
960
960
960
960
960
22099
 27037
 31953
 36869
 41785
46701
51617
2468
2445
2377
2271
2096
1877
1615
2368
2295
2168
1992
1738
1430
1069
Y225M-6
30kW,380V
Y250M-6
37kW,380V
G5-51-1No.14.0F
1450
1450
1450
1450
1450
1450
1450
53004
64848
76639
88430
100220
112011
123802
7662
7592
7381
7053
6508
5828
5016
7351
7127
6731
6188
5396
4440
3320
Y315L₂-4
200kW,380V
Y355-4
220kW/280kW,6000V
G5-51-1No.14.0F
960
960
960
960
960
960
960
35092
42934
50740
58547
66353
74159
81965
3359
3328
3235
3092
2853
2555
2199
3223
3124
2950
2713
2366
1946
1456
Y315S-6
75kW,380V
Y315M-6
90kW,380V


Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch
Category
Get in Touch