G4-73 Y4-73 Boiler Centrifugal Fan for Industrial Ventilation

The G4-73 and Y4-73 boiler centrifugal fans are designed for steam boilers in thermal power plants and can also be used for mine and general ventilation. These high-pressure centrifugal fans operate with flue gas temperatures up to 250°C and air temperatures up to 80°C. Featuring both right-hand and left-hand rotations, these fans ensure high efficiency, low noise, and reliable performance. They are ideal for industrial applications where robust ventilation is required.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
G4-73 Y4-73 Boiler Centrifugal Fan for Industrial Ventilation

Application

G4-73 and Y4-73 boiler induced draft fans are suitable for induced draft fan systems of steam boilers below 670V/h in thermal power plants. G4-73 can also be used for mine ventilation and general ventilation when there are no other special requirements. The medium conveyed by the ventilator is air, and the maximum temperature shall not exceed 80°C; the medium conveyed by the induced draft fan is flue gas, and the maximum temperature shall not exceed 250°C. A dust removal device must be installed in front of the induced draft fan to minimize the dust content of the flue gas entering the fan. According to the general use of power plants, the dust removal efficiency shall not be less than 85%.


Type

  • 1. The ventilator and induced draft machine are single suction, with 12 machine numbers from No.8 to No.28.
  • 2. When viewed from the motor end, if the impeller rotates clockwise, it is called a right-hand cyclone fan, represented by "right"; if the impeller rotates counterclockwise, it is called a left-hand cyclone fan, represented by "left".
  • 3. The air outlet position of the fan is expressed as the air outlet angle of the casing.
  • 4. The fan transmission mode is D type, and elastic coupling is used for transmission.

Structural characteristics

The fan is mainly composed of an impeller, a casing, an air inlet, an adjusting door, and a transmission part.

  • 1. The impeller consists of 12 backward-inclined wing-shaped oblique blades welded between the conical front disc and the flat rear disc. The use of wing-shaped blades ensures high efficiency, low noise, and high strength of the fan. The impeller is calibrated for static and dynamic balance, so it runs smoothly. The impeller structure of the induced draft fan and the induced draft fan of the same machine number is the same.
  •  
  • 2. The casing is a volute body welded from ordinary steel plates. The casing of the single-suction large fan is made into three different forms: No. 8~12 casings are made into an integral structure and cannot be disassembled; No. 14-No. 16 casings are made into two-opening type; No. 18-No. 28 casings are made into three-opening type. The induced draft fan and volute plate are appropriately thickened to prevent wear.
  •  
  • 3. The convergent and streamlined air inlet is made into an integral structure and fixed to the inlet side of the fan with bolts.
  •  
  • 4. The regulating door is a device used to adjust the fan flow rate. It is installed axially in front of the air inlet. The adjustment range is from 0° (fully open) to 90° (fully closed). The lever position of the regulating door is on the right side when viewed from the air inlet. For a right-handed fan, pushing the lever from bottom to top is from fully closed to fully open; for a left-handed fan, pulling the lever from top to bottom is from fully closed to fully open.
  •  
  • 5. The main shaft of the transmission part is made of high-quality steel and is supported by rolling bearings. There are two types of bearing boxes: No.8No.16 use an integral simple bearing box; No.18No.28 use two independent pillow bearing boxes. The bearing box is equipped with a thermometer and an oil level indicator (only for induced draft fans). The lubricating oil uses the full-loss system oil L - AN46, and the amount of oil added is in accordance with the requirements of the oil level mark. If grease is used for the integral simple bearing box of No.8-No.16, an oil baffle plate should be added on the side of the ball in the bearing box, and its fixing groove has been prefabricated. The induced draft fan is equipped with a water cooling device, so a water pipe must be installed. The water consumption varies with the temperature and is generally considered to be 0.5~1 m³/h.

Performance and selection

For G4-73 and Y4-73 fans, only the performance table and performance curve of dimension 1 of the No.10 model are given. Based on the performance table or performance curve of dimension 1, the dimensioned performance of all models No.8~No.28 can be calculated. For the treatment of excessive or insufficient flow during fan use and new installation and operation, refer to the Y4-70 centrifugal induced draft fan.
G4-73 Y4-73 Boiler Centrifugal Fan for Industrial Ventilation
No. Rotating Rate /(r/min) Air Flow /(m³/h) Pressure/Pa Efficiency(%) Power /kW
8D 1450  16156  2104  79.4   
18244  2095  83.2  18.5 
20442  2072  85.7 
22530  2018  87 
24618  1924  86.8 
26706  1794  85.6 
28904  1611  82.8 
30993  1400  79.4 
9D 1450  23003  2668  79.4  30 
25976  2656  83.2 
29106  2628  85.7 
32079  2559  87 
35052  2440  86.8  37 
38026  2275  85.6 
41155  2042  82.8 
44128  1775  79.4 
960  15229  1163  79.4  11 
17108  1158  83.2 
19270  1146  85.7 
21238  1116  87 
23207  1064  86.8 
25175  993  85.6 
27247  891  82.8 
29216  775  79.4 
10D 1450  31554  3301  79.4  55
35633  3282  83.2 
39926  3251  85.7 
44004  3166  87 
48083  3018  868 
52161  2813  85.6 
56455  2525  828 
60533  2194  79.4 
960  20891  1437  79.4  15 
23591  1431  83.2 
26434  1416  85.7 
29134  1379  87 
31834  1315  86.8  18.5 
34534  1226  85.6 
37377  1101  82.8 
40077  958  79.4 
730  15886  829  79.4  7.5 
17939  826  83.2 
20100  812  85.7 
22154  796  87 
24207  759  86.8 
26260  708  85.6 
28422  636  82.8 
30475  553  79.4 
11D 1450  41999  4003  79.4  75 
47427  3986  83.2 
53142  3943  85.7  90
58570  3840  87 
63998  3660  86.8 
69427  3411  85.6 
75141  3060  82.8 
80570 2659 79.4
960  27806  1741  79.4  22 
31400  1734  83.2 
35183  1715  85.7  30 
38777  1671  87 
42371  1593  86.8 
45965  1485  85.6 
49748  1334  82.8 
53343  1160  79.4 
730  21144  1004  79.4  11 
23877  1000  83.2 
26754  989  85.7 
29487  964  87 
32220  919  86.8 
34953  857  85.6 
37829  770  82.8 
40562  669  79.4 
12D 1450  54526  4777  79.4  132 
61574  4756  83.2 
68992  4705  85.7
76040  4582  87 
83088  4366  86.8  160 
90135  4069  85.6 
97554  3650  82.8 
104600  3171  79.4 
960  36100  2075  79.4  37 
40766  2066  83.2 
45677  2044  85.7 
50344  1990  87  45 
55010  1898  86.8 
59676  1769  85.6 
64587  1588  82.8 
69253  1381  79.4 
730  27451  1196  79.4  15 
30999  1191  83.2 
34734  1178  85.7  18.5 
38282  1148  87 
41830  1094  86.8 
45378  1020  85.6 
49113  916  82.8 
52661  797  79.4 
14D 1450  86586  6541  79.4  280 
97777  6513  83.2 
109550  6442  85.7 
120740  6272  87 
131940  5975  86.8  315 
143130  5566  85.6 
154910  4990  82.8 
166100  4333  79.4 

G4-73 Y4-73 Boiler Centrifugal Fan for Industrial Ventilation
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Russian Client's Positive Feedback on Decent
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed
 
 
Centrifugal Fan Factory Tour    
FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.