G/Y6-51-1 F Type High-Pressure Boiler Fan for Industrial Use

The G/Y6-51-1 F type boiler fan and induced draft fan are designed for use in thermal power plants, offering efficient handling of air and flue gases. This industrial centrifugal fan is capable of operating at air temperatures up to 80℃ and flue gas temperatures up to 250℃. The fan is available in both right-hand and left-hand configurations and features a single-suction design for optimized performance in industrial environments.

  • Overview
  • Features
  • Parameter
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
G/Y6-51-1 F Type High-Pressure Boiler Fan for Industrial Use

Overview

The G/Y6-51-1 F type boiler fan and induced draft fan are designed for efficient use in thermal power stations.
 

Operating conditions

The fan handles air at temperatures up to 80℃, while the induced draft fan manages flue gases at up to 250℃.
 

Model range

The fan and induced draft fan feature a single-suction design and are available in 14 models, from No. 8 to No. 31.5.
 

Rotation direction

This fan can rotate either clockwise or counterclockwise. Viewed from the motor side, a clockwise rotation indicates a right-hand fan, and counterclockwise rotation denotes a left-hand fan.
 

Main components

The fan is composed of an impeller, casing, air inlet, adjusting door, and transmission parts.
① Impeller: Made from backward-inclined blades, welded between a conical front disc and a flat rear disc for enhanced performance.
② Casing: Manufactured from welded steel plates, the casing forms a robust volute design.
③ Air Inlet: The air inlet has a convergent streamlined structure, bolted to the front cover for secure installation.
④ Transmission: Comprising a high-quality steel main shaft, bearing box, and coupling. The F-type transmission uses a double-support structure with ball bearings for stability.

Performance of G6-51-1 Boiler Centrifugal Fan
(Altitude 0 km, Inlet Temperature 20°C, Gas Density 1.200 kg/m³, Outlet Equivalent Area 0.3300)
Rotating Rate/(r/min) Air Flow (m³/h) Pressure /Pa Moter Specific Speed
G6-51-1No.8.0F
1450
1450
1450
1450
1450
1450
1450
9900
12100
14400
16500
18700
20900
23100
2699
2656
2568
2479
2346
2214
2036
Y180M-4
18.5kW,380V
35.6
39.8
44.5
49
54.3
60
67.1
Y180L-4
22kW,380V
G6-51-1No 9 0F
1450
1450
1450
1450
1450
1450
1450
14096
17228
20503
23493
26626
29758
32890
3416
3362
3250
3137
2969
2802
2577
Y200L-4
30kW,380V
35.6
39.8
44.5
49
54.3
60
67.1
Y225S-4
37kW,380V
Y225M-4
45kW,380V
G6-51-1No.10.0F
1450
1450
1450
1450
1450
1450
1450
19336
23633
28125
32227
36523
40820
45117
4217
4150
4013
3873
3666
3459
3181
Y225M-4
45kW,380V
35.6
39.8
44.5
49
54.3
60
67.1
Y250M-4
55kW,380V
Y280S-4
75kW,380V
G6-51-1No.11.0F
1450
1450
1450
1450
1450
1450
1450
25736
31455
37434
42894
48613
54332
60051
5103
5022
4855
4687
4435
4186
3849
Y280S-4
75kW,380V
35.6
39.8
44.5
49
54.3
60
67.1
Y280M-4
90kW,380V
Y315S-4
110kW,380V
G6-51-1No.11.0F
960
960
960
960
960
960
960
17039
20825
24784
28399
32185
35972
39758
2237
2201
2128
2054
1944
1835
1687
Y200L2-6
22kW,380V
35.6
39.8
44.5
49
54.3
60
67.1
Y225M-6
30kW,380V
Y250M-6
37kW,380V
G6-51-1No.12.0F
1450
1450
1450
1450
1450
1450
1450
33413
40838
48600
55688
63113
70538
77963
6073
5976
5778
5578
5279
4982
4581
Y315S-4
110kW,380V
35.6
39.8
44.5
48.9
54.3
60
67.1
Y315M1-4
132kW,380V
Y315M2-4
160kW,380V
G6-51-1No.12.0F
960
960
960
960
960
960
960
22121
27037
32177
36869
41785
46701
51617
2662
2619
2533
2445
2314
2184
2008
 Y225M-6
30kW,380V
35.6
39.8
44.5
48.9
54.3
60
67.1
 Y250M-6
37kW,380V
 Y280S-6
45kW,380V
 Y280M-6
55kW,380V
G6-51-1No.14.0F
1450
1450
1450
1450
1450
1450
1450
53058
64848
77175
88430
100220
112011
123802
8266
8134
7865
7592
7185
6780
6235
Y355-4
220kW/250kW/
280kW/315kW,
    6000V
35.6
39.8
44.5
49
54.3
60
67.1
Y400-4
355kW,6000V
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.