G/Y6-48 High-Pressure Centrifugal Fan for Boiler Systems

The G/Y6-48 high-pressure centrifugal fan is designed for boilers with evaporation capacities from 0.5 to 20 t/h. This industrial centrifugal blower effectively manages air and flue gas flow in boiler systems, working at temperatures from 20°C to 200°C. With right-hand and left-hand configurations available, this versatile fan is ideal for a range of industrial applications.

  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
G/Y6-48 High-Pressure Centrifugal Fan for Boiler Systems

Purpose

The G/Y6-48 centrifugal fan is suited for use in boilers with an evaporation capacity between 0.5 and 20 t/h. This centrifugal blower is ideal for controlling air and flue gas flow in demanding industrial environments. The fan efficiently manages air at 20°C, while the induced draft fan is capable of handling flue gas at up to 200°C. Both fans feature a single-suction design for streamlined operation.
 

The G6-48 series includes models ranging from No.2.8A to No.10D, while the Y6-48 series covers No.4.5D to No.12D. The fan's rotation direction is defined by the orientation of the impeller: clockwise for right-hand and counterclockwise for left-hand. The outlet angle is determined by the casing design.

Performance of G6-48-11 Model Boiler Centrifugal Fan
No. Rotating Speed (r/min) Media Temperature /℃ Full Pressure /Pa Air Flow /(m³/h) Power /kW
2.8A 2830  20  625
932
1192
1220
1294
1363
1367
1395
1859
1519
1240
1134
1000
  790
 685
577
0.75 
3.3A 2830  20  835
1070
1257
468
1549
1623
1740
1763
2801
2590
2337
2071
1900
1789
1544
1159
1.1 
5.4A 1430  20  916
1040
1111
1189
1255
1263
1294
1330
5896
5051
4670
4293
3600
3282
2860
2367
3.0 
6.4A 1440  20  1441
1553
1615
1722
1823
865
1873
1884
9884
8573
7921
7148
6010
5354
4650
3866
5.5 
7.3A 1440  20  1743
 1955
2033
2212
 2275
 2301
 2414
2477
12551
11184
10662
8498
7500
7085
6000
5437
7.5 
8A 1460  20  2021
2179
2302
2546
2736
2798
2861
2925
13203
  12484
11639
  10391
   9103
   8415
   7727
   7038
11 
8.5A 1470  20  2247
2286
2805
3004
3196
3256
3295
3369
21201
  19734
  18431
16445
14500
  13500
   2455
   9645
18.5 
10D 1480  20  2149
 2702
2950
3196
 3205
 3520
 3765
3961
43491
37781
35270
32602
32509
29330
25721
21991
45 
 
Performance of Y6-48-11 and Y6-48-12 Model Boiler Induced Draft Fans
No. Rotating Speed (r/min) Media Temperature /℃ Full Pressure /Pa Air Flow /(m³/h) Power /kW
Y6-4811
4.5D
2870 200 1469
1821
2012
2240
2453
2471
2495
2530
4601
3854
3464
2912
2200
1901
1700
1565
3.0 
Y6-48-11
5D
2900  200  1112
1721
2163
2505
2647
2813
2844
2880
8924
7472
6200
5124
4400
3842
3500
2923
5.5 
Y6-48-12
5D
2890  200  1047
1324
1507
1686
1885
2135
2222
2293
5721
5192
4902
4592
4175
3479
3016
2560
4.0 
Y6-48-11
5.4D
2930  200  2171
2378
2619
2845
2902
3063
3162
3200
10368
9511
8785
8046
7501
6539
5486
4270
11 
Y6-48-11
6D
2940  200  1212
1669
2048
2523
3186
3398
3461
3715
20456
19768
17915
15924
14000
12998
11408
8076
22 
Y6-48-12
5.4D
2900  200  1257
1810
1922
2158
2318
2445
2575
2706
8798
7752
7357
6877
6415
5689
5100
3947
7.5 
Y6-48-12
6D
2930  200  1582
1787
2085
2605
2745
3152
3390
3531
16147
15483
14491
13282
12632
1473
10588
8798
18.5 
Y6-48-11
10D
1480  200  2561
2704
2833
2982
3137
3196
3213
3236
37583
3457
  31330
27888
  24000
  20077
  18849
  16800
37 
Y6-48-11
11.2D
1480  200  1251
2447
2784
2885
3034
3145
3200
3376
57485
 48839
  40522
 38833
 36586
  33834
  31582
 28149
55 
Y6-48-11
12D
1490  200  2376
2586
2807
3042
3273
3436
3634
3670
82581
 77814
 72509
 66671
  60911
  53400
  45136
 36080
90 
Y6-48-12
10D
1480  200  2614
2747
2966
3076
3087
3233
3254
3297
30883
 28324
  24959
 21402
  20002
  17217
  15000
 11000
30 


Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch
Category
Get in Touch