G/Y6-41 Series Industrial Boiler Fans for Draft and Induced Draft Applications

The G/Y6-41 series industrial centrifugal fans are designed to optimize airflow for boiler systems with an evaporation range of 0.5 to 10 t/h. These high-efficiency centrifugal blowers are available for both draft and induced draft purposes, offering reliable performance in demanding industrial environments. With various rotation angles and machine configurations, these industrial fans ensure smooth, quiet, and efficient operation.

  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
G/Y6-41 Series Industrial Boiler Fans for Draft and Induced Draft Applications

Purpose

The G/Y6-41 series centrifugal fans are engineered for use in industrial boiler systems. These fans provide both draft and induced draft capabilities, making them ideal for boilers with an evaporation capacity between 0.5 and 10 t/h. These industrial fans deliver efficient air circulation and exhaust management.

Applicable Environment

The draft fan can operate in temperatures up to 50°C (with a maximum of 80°C), while the induced draft fan can handle temperatures up to 200°C (maximum 250°C). The fan is also capable of managing environments where dust and particulate levels do not exceed 150mg/m³, ensuring performance stability even in harsh conditions.
 

Machine Numbers

This series includes 6 machine numbers for the draft fans: No. 2.5A, 3.3A, 5.4A, 6.4A, 7.1A, and 8.5A. For the induced draft fans, 8 machine numbers are available: No. 3.55C, 4C, 4.5C, 5.4C, 7.1C, 9C, 10C, and 11.2D.

Rotation and Configuration

These centrifugal blowers come in both right-handed and left-handed versions. When viewed from the motor side, if the impeller rotates clockwise, it is termed right-handed; if counterclockwise, it is left-handed. The outlet angle for both right-hand and left-hand fans can be configured to 0°, 90°, 180°, and 270°. Additionally, these fans can be equipped with A or D transmission modes for draft fans, and C or D transmission modes for induced draft fans.

Structural Overview

  • 1. Impeller – The impeller is crafted from backward-inclined arc blades and welded between an arc-conical wheel cover and a flat wheel disc. It undergoes precise balancing to ensure smooth, quiet operation with high efficiency and minimal vibration.
  • 2. Casing – Constructed from robust steel plates, the casing is volute-shaped for durability. It can be assembled either as a separate component or welded directly to the support structure.
  • 3. Air Inlet – The streamlined air inlet is designed to enhance airflow, bolted securely on the inlet side to minimize losses and optimize air intake efficiency.
  • 4. Transmission System – This includes a main shaft, integral bearing box, rolling bearings, and either pulleys or couplings. The transmission is lubricated using L-AN32 oil for optimal performance and longevity.

Performance and Selection

The G/Y6-41 series high-pressure centrifugal fans offer versatile performance for a range of industrial boiler applications. To select the appropriate fan, consider the required pressure and airflow based on specific operational conditions.
(Rotation Speed 2825 r/min, Altitude 0 km, Fan Inlet Temperature 20°C, Fan Inlet Gas Density 1.2 kg/m³, Outlet Equivalent Area 0.2016)
Air Flow /(m³/h) Pressure /Pa Static Pressure /Pa Power /kW  Design Conditions
G6-41-15No.3.3A②
2186
2053
1918
1748
1577
1433
1243
835
931
1095
1234
1377
1491
1597
376
526
742
941
1138
1294
1449
1.1  Full Pressure: 1370Pa
Air Flow: 1850m³/h
G6-41-16No.3.3A②
2439
2291
2140
1950
1760
1598
1386
1110
1238
1456
1641
1831
1983
2123
539
734
1016
1276
1533
1738
1938
1.5  Full Pressure: 1370Pa
Air Flow: 1850m³/h

G/Y6-41 Series Industrial Boiler Fans for Draft and Induced Draft Applications
G/Y6-41 Series Industrial Boiler Fans for Draft and Induced Draft Applications
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch