CF Series Multi-Blade Industrial Centrifugal Fan for Kitchen Ventilation

The CF series multi-blade centrifugal fan is a high-efficiency, energy-saving, low-noise medium-pressure centrifugal fan designed for kitchen purification and ventilation in hotels, restaurants, and public places. This centrifugal blower efficiently transports air or non-hazardous gases, making it ideal for fume extraction in various industrial and commercial settings. With a focus on performance and durability, this industrial centrifugal fan ensures optimal air circulation and purification.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
CF Series Multi-Blade Industrial Centrifugal Fan for Kitchen Ventilation

Application

CF series multi-wing centrifugal fans are new high-efficiency, energy-saving, low-noise medium-pressure fans that absorb advanced foreign technology and are used for the increasingly developed kitchen purification and hotel and restaurant ventilation in China. They are widely used for ventilation and fume extraction in kitchens, hotels, restaurants, factories, mines, and public places. The medium to be transported is air or other non-self-igniting and harmless gases to the human body. The medium does not contain sticky substances, the temperature is ≤80°C, and the dust and hard particles are ≤100mg/m³.

Structure

This centrifugal fan is a single suction type, with six machine numbers: 2A, 2.5A, 3A, 3.5A, 4A, and SA. The fan can be made into two forms: right-handed and left-handed. Looking from the motor end, the impeller rotates clockwise for a right-handed centrifugal blower, represented by "right"; the opposite is "left". The air outlet position of the centrifugal fan can be made into 0°, 90°, 180°, and 270°, which is applicable to both left and right rotation. This centrifugal fan is mainly composed of an air inlet, an impeller, a casing, a motor, and a bracket. The machine booth store uses ordinary steel plates to weld the volute casing as a whole. The air inlet is made of ordinary steel plates to form a convergent streamline and welded to the front cover plate to form an integral structure. The impeller is made of 40-60 thin plate arc blades riveted with the wheel disc and wheel cover, and is corrected for static and dynamic balance. It has good aerodynamic performance and runs smoothly.

No. Rotating Speed(r/min) Air Flow(m³/h) Full Pressure/Pa Power/kW
1.5A 2900 830  790  0.55
875  788 
925  78 
975  772 
1025  756 
1080  736 
2A 2800  1250  1022  1.1
1400  1015 
1550  994 
1700  950 
1850  893 
2000  830 
2250  693 
1400 625  256  0.37
700  254 
775  249 
850  238 
925  223 
1000  208 
1125  173 
2.5A 1450  950  462  0.55 
1130  485 
1310  493 
1490  488 
1670  469 
1850  441 
2000  410 
1400  917  431  0.55 
1091  452 
1265  460 
1439  455 
1612  437 
1786  411 
1931  382 
2.5A 2900  748  1542  2.2 
1045  1633 
1328  1652 
1691  1655 
2011  1564 
2274  1455 
2617  1296 
2.5A 2800  722  1437  2.2 
1009  1522 
1282  1540 
1633  1543 
1942  1458 
2196  1356 
2527  1208 
3A 1400  2033  725  1.5 
2283  709 
2533  688 
2783  666 
3033  641 
3283  604 
3500  588 
1400  1963  676  1.1 
2204  661
2446  641 
2687  621 
2928  598 
3170  563 
3379  548 
910  1276  286  0.55 
1433  279 
1590  271 
1747  262 
1903  253 
2061 238 
2196  232 
3.5A 1450  3233  1000 
3533  1004 
3833  993 
4133  987 
4433  973 
5733  945 
5000  917 
1400  3122  932  2.2 
3411  936 
3701  926 
3990  920 
4280  907 
4570  881 
4828  855 
910  2029  394  0.75 
2217  395 
2406  391 
2594  389 
2782  383 
2971  372 
3138  361 
4A 1450  4000  1428  5.5
4433  449 
4867  1459 
5300  1454 
5733  1439 
6233  1392 
6500  1355 
4A 1440   3972   1408  5.5 
 4402   1429 
 4833   1439 
 5263   1434 
 5693   1419 
 6190   1373 
 6455   1336 
940   2593   600  1.5 
 2874   609 
 3155   613 
436  61 
 3716   605 
 4041   585 
 4214   569 
4.5A 960   4500   764 
 4833   773 
 5176   772 
 5500   767 
 5833   754 
 6167   714 
 6500   630 
5A 960   3233   790 
 3600   798 
 3967   789 
 4333   763 
 4700   714 
 5067   637 
 5500    497 

CF Series Multi-Blade Industrial Centrifugal Fan for Kitchen Ventilation
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment

Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.