9-28 Series Centrifugal Fan for Forging Furnaces and High-Pressure Ventilation

The 9-28 Series Centrifugal Fan is a high-pressure centrifugal blower designed for industrial applications such as forging furnaces and material transport. This industrial centrifugal fan handles non-corrosive, non-viscous gases up to 80°C and is suitable for environments with dust and fine particles up to 150 mg/m³. Ideal for various high-pressure ventilation needs.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
9-28 Series Centrifugal Fan for Forging Furnaces and High-Pressure Ventilation

Application

The 9-28 Series Centrifugal Fan is generally used for forging furnaces and high-pressure forced ventilation, and is widely used for material transportation. This type of centrifugal blower can transport air and non-corrosive, non-viscous gases. The temperature of the transported medium generally does not exceed 80 degrees Celsius; the dust and hard fine particles contained in the medium are not more than 150 mg/m³. This type of centrifugal blower can also be used as a high-temperature centrifugal fan for special occasions such as cement kiln decomposition process (machine number 16 or above), steel smelting, etc. (use heat-resistant, high-strength materials instead).


Flow rate and pressure range

The 9-28 Series Centrifugal Fan has a flow rate range: single suction is 200-30,000 m³/h; double suction is 2,200-600,000 m³/h. Pressure range: 3,430-19,700 Pa.

Type

① This type of centrifugal fan has two types: single suction and double suction. The machine numbers (No.) are 4, 4.5, 5, 5.6, 6.3, 7.1, 8, 9, 10, 11.2, 12.5, 14, 16, 17, 18, 20, 21, 22, 23, 24, a total of 20 machine numbers.

② This type of centrifugal blower can be made into two types: right-handed or left-handed. Looking from the motor side, if the impeller rotates clockwise, it is called a right-handed centrifugal fan, represented by "right"; if it rotates counterclockwise, it is called a left-handed centrifugal fan, represented by "left".

③ The outlet position of the centrifugal fan is indicated by the outlet angle of the casing. Both "right" and "left" can be made into 0°, 45°, 90°, 135°, 180°, and 225°, a total of 6 angles.

④ The centrifugal fan transmission modes are A type (No. 4-No. 6.3), D type (No. 7.1-No. 16), and E type.
 

Structure

Fans of No. 4-No. 6.3 are mainly composed of impeller, casing, air inlet, bracket, etc. Fans of No. 7.1-No. 24 are mainly composed of impeller, casing, air inlet, transmission part, etc. F-type transmission is mainly composed of impeller, casing, air inlet, air inlet box, transmission part, etc. Fans can also be equipped with adjustable doors according to user needs. The 9-28 Series Centrifugal Fan has 16 long blades and 16 short blades. After the impeller is formed, it is calibrated for static and dynamic balance, and runs smoothly and reliably. ② The casing is welded with ordinary steel plates into a volute casing. For high-temperature centrifugal fans, heat-resistant materials can be selected according to the temperature conditions, and the casing can also be made into split parts. ③ The air inlet is made into a convergent streamlined overall structure and fixed with a front cover assembly with bolts. ④ The dynamic transmission group consists of the main shaft, bearing box, coupling, etc. The main shaft can be made of high-quality steel or heat-resistant steel according to different uses. Ball bearings or sliding bearings are used. Ball bearings are lubricated with bearing grease, and sliding bearings are lubricated with thin oil.


Performance and Selection

The performance of this type of industrial centrifugal fan is converted according to the dimensionless operating point performance table of the centrifugal fan.

  • The design and use units shall determine the machine number and required power from the performance table and select the motor according to the selected flow rate and total pressure. Other types of motors may also be selected, but the speed and power must be appropriate and shall be indicated when ordering.
  • The performance of each speed in the performance table is divided into 8 operating points according to the flow rate. The performance table shall prevail when ordering.
  • The performance of qualified centrifugal fans leaving the factory is that the total pressure value deviation is +5% at a given flow rate.
  • The parameters provided in the performance table are calculated based on the standard state of the centrifugal fan inlet, that is, temperature t = 20°C, atmospheric pressure: p a = 10300 Pa, relative humidity φ is 50%, and gas density ρ = 1.2 kg/m³. If the centrifugal fan is not used under standard conditions, the performance should be calculated based on the standard conditions. About formula conversion.
No. Rotationg Speed (r/min) Full Pressure /Pa Air Flow (m³/h) Effiency(%) Power/kW Moter
Mo. Power/kW
4A 2900  3893
3884
3835
3776
3707
3629
3540
3452
2198
2473
2748
3022
3297
3572
3847
4122
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
3.35
3.71
4.07
4.44
4.81
5.17
5.55
5.95
Y112M-2
Y132S1-2
Y132S2-2
4
5.5(5.5)
7.5
4.5A 2900  4933
4623
4854
4776
4698
4599
4482
4374
3130
3521
3912
4303
4695
5086
5477
5868
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
6.05
6.70
7.34
8.00
8.68
9.34
10.01
10.73
Y132S2-2
Y160M1-2
7.5
11
5A 2900  6090
6071
6002
5894
5796
5678
5531
5394
4293
4830
5367
5903
6440
6977
7513
8050
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
10.24
11.34
12.45
13.55
14.70
15.81
16.95
18.15
Y160M2-2
Y160L-2
15
18.5
5.6A 2900  7640
7620
7522
7394
7277
7120
6943
6767
6032
6786
7540
8294
7048
7802
10555
11309
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
18.06
19.99
21.93
23.88
25.93
27.86
29.89
31.99
Y180M-2Y200L1-2Y200L2-2 223037
6.3A 2900  9670
9610
9523
9356
9209
9003
8787
8571
8588
9662
10735
11809
12882
13956
15029
16103
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
32.54
36.01
39.52
43.03
46.71
50.15
53.86
57.69
Y225M-2
Y250M-2
Y280S-2
45
55
75
7.1D 2900  12278
12249
12092
11886
11690
11445
11160
10886
12293
13829
15366
16903
18439
19976
21512
23049
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
60.35
66.83
73.30
79.84
86.61
73.13
99.92
107.02
Y280S-2
Y315S-2
15
110
8D 2900  15583
15554
15358
15093
14848
14524
14171
13818
17585
19783
21981
24180
26378
28576
30774
32972
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
109.57
121.39
133.18
145.03
157.37
169.06
181.50
194.33
Y315M1-2Y355M1-2 132
200
8D 1450  3893
3884
3835
3776
3707
3629
3540
3452
8793
9892
10991
12090
13189
14288
15387
16486
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
13.69
15.16
16.63
18.14
19.65
21.12
22.67
24.27
Y180M-4
Y200L-4
18.5
30
9D 1450  4933
4923
4854
4776
4698
4599
4482
4374
12519
14084
15649
17214
18779
20344
21908
23473
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
24.69
27.35
29.97
32.67
35.45
38.12
40.86
43.79
Y200L-4
Y225M-4
30
45
10D 1450  6090
6071
6002
5894
5796
5678
5531
5394
17173
19320
21466
23613
25759
27906
30053
32199
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
41.82
46.27
50.83
55.31
59.99
64.55
69.18
74.08
Y250M-4
Y280S-4
55
75
11.2D 1450  7640
7620
6522
7394
7277
7120
6943
6767
24127
27143
30158
33174
36190
39206
42222
45238
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
73.70
81.60
89.49
97.48
105.82
113.71
122.01
130.57
Y315S-4
Y315M1-4
110
32
11.2D 960  3344
3344
3295
3246
3187
3119
3040
2972
15974
17970
19967
21964
23960
25957
27954
29950
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
21.36
23.71
25.96
28.33
30.69
32.97
35.37
37.96
Y225M-6
Y250M-6
30
37
12.5D 1450  9513
9493
9375
9209
9062
8866
8650
8434
33541
37734
41926
46119
50311
54504
58697
62889
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
127.58
141.32
155.07
168.78
183.19
196.83
211.30
226.24
Y315M2-4
Y355M2-4
160
250
12.5D 960  4168
4158
4109
4040
3972
3884
3795
3697
22206
24982
27758
30534
33310
36085
38861
41637
81.5
82.6
82.6
81.0
81.1
80.0
78.3
76.4
37.01
40.98
45.00
49.03
53.16
57.08
61.38
65.66
Y280S-6
M315S-6
46
75
14D 1450  1935
11906
11759
11553
11366
11121
10847
10582
47123
53013
58903
64794
70684
76574
82465
88355
81.5
82.6
82.6
82.0
81.1
80.0
78.3
76.4
224.88
246.00
273.25
297.47
322.82
346.88
372.26
398.79
Y355M2-4 250 

9-28 Series Centrifugal Fan for Forging Furnaces and High-Pressure Ventilation
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment

Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch
Category
Get in Touch