4-79 Type Centrifugal Fan For Indoor Ventilation In General Factories

The 4-79 centrifugal fan is designed for indoor ventilation in factories and large buildings. It efficiently handles air and non-corrosive gases, with low noise and high efficiency. The fan is available in both clockwise and counterclockwise rotations, with adjustable outlet positions for flexible installation. Suitable for air volumes containing minimal dust and hard particles, this fan ensures reliable performance up to 80°C. Ideal for general industrial applications.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
4-79 Type Centrifugal Fan For Indoor Ventilation In General Factories

Application

The F4-72 fan, made of stainless steel, is used to convey corrosive gases, maintaining the same performance and foundation dimensions as the 4-72 model.The 4-79 centrifugal fan is ideal for indoor ventilation in general factories and large buildings. It effectively handles air and non-corrosive gases, ensuring safety and efficiency. The gas transported must be non-self-igniting, non-toxic, and free from sticky substances, with dust and hard particles not exceeding 150mg/m³, and temperatures not surpassing 80°C.

Type

Available in clockwise and counterclockwise rotations, the fan's direction is determined by the impeller rotation when viewed from the motor end. The right-hand fan rotates clockwise, while the left-hand fan rotates counterclockwise. The outlet position of the fan is indicated by the outlet angle of the casing. Fans from No. 3 to No. 12 are manufactured in a single type for user convenience, allowing installation at the required position without specifying during ordering. No. 3 outlet position adjustment range is 0°225°, at intervals of 45°. The adjustment range for No. 3.5No. 6 is 0°225° at intervals of 22.59°, with A-type transmission. No. 7No. 8 outlet position adjustment range is 0°180°, at intervals of 22.59°, with C-type transmission. Fans No. 10No. 20 have an E-type transmission mode, with fixed outlet positions of 0°, 90°, and 180° that must be specified when ordering. Double air inlet forms for No. 10~No. 20 also have fixed positions and E-type transmission.
 
4-79 Type Centrifugal Fan For Indoor Ventilation In General Factories

Overall Structure

Fans No. 3No. 6 in the 4-79 series include impellers, casings, and air inlets, directly connected to the motor. Fans No. 7No. 20 include these parts plus transmission components.
Impeller: Features 16 backward-inclined arc thin-plate blades, a curved front disc, and a flat rear disc made of steel plates. Balanced for optimal air performance, high efficiency, low noise, and smooth operation.
Casing: No. 3No. 12 casings are made as a single piece and cannot be disassembled. Casings for No. 14No. 20 are in two parts, joined by bolts along the horizontal plane.
Air Inlet: An integral part installed on the fan's side, with a curved axial cross-section to facilitate smooth gas entry with minimal loss.
Transmission Part: Comprising the main shaft, bearing box, rolling bearing, and pulley.
 

Performance and selection

Fan Performance: Parameters such as air volume, total pressure, shaft speed, power, and efficiency define the fan's performance, with interdependent relationships between them.
 
Fan Selection: The performance parameters listed reflect standard air condition performance. For non-standard conditions, convert performance to standard conditions using relevant formulas before selecting from the performance table. Throttling devices are commonly used for flow rate adjustments but may waste energy if the actual flow rate significantly exceeds requirements. Adjusting fan speed or replacing the fan with a lower-pressure model is more economical. If the throttling device is fully open and flow remains too low, modify the pipe network to reduce resistance or increase fan speed. Belt-driven fans can adjust speeds by changing pulley diameters, but the maximum speed should not exceed the performance table's specified limit.
4-79, 4-2×79Performance and optional parts of centrifugal fans
Rotating Speed/(r/min) Wind Speed/(m/s) Complete Pressure/Pa Air Flow/(m³/h) Moter
No Power/kW
4-79No.3A
2900 7.2
8.0
8.5
9.6
10.2
11.0
12.3
13.5
1196
1167
1157
1118
1069
1040
892
726
1970
2180
2430
2670
2900
3130
3480
3830
Y90S-2
(B35)
1.5
1450 3.5
4.0
4.5
4.9
5.3
5.7
6.4
7.0
304
294
284
275
265
255
226
177
990
1100
1220
1340
1450
1560
1740
1910
Y802-4
(B35)
0.75
4-79No.3.5A
2900 8.4
9.3
10.3
11.4
12.3
13.3
14.8
16.3
1628
1589
1569
1510
1461
1422
1206
981
3120
3460
3860
4240
4600
4960
5520
6070
Y100L-2
(B35)
3
1450 4.2
4.7
5.2
5.7
6.2
6.7
7.4
8.2
412
402
392
382
363
353
304
245
1560
1750
1930
2120
2300
2480
2760
3040
Y90S-4
(B35)
1.1
4-79No.4A
2900 9.6
10.7
11.9
13.0
14.1
15.2
16.9
186
2138
2079
2050
1981
1902
1853
1579
1275
4670
5220
5760
6310
6860
7410
8240
9080
Y132S1-2
(B35)
5.5
1450 4.8
5.35
5.9
6.5
7.0
7.6
8.5
9.3
530
520
510
490
481
461
392
324
2330
2610
2880
3160
3430
3710
4120
4540
Y90S-4
(B35)
1.1
4-79No.4.5A
2900 10.8
12.1
13.3
14.6
15.9
17.1
19.1
21.0
2697
2628
2599
2511
2412
2344
2001
1618
6640
7440
8200
8990
9790
10550
11720
12920
Y160M1-2
(B35)
11
1450 5.4
6.0
6.7
7.3
7.9
8.6
9.5
10.4
677
657
647
628
598
588
500
402
3320
3720
4110
4510
4890
5270
5860
6450
Y90L-4
(B35)
1.5
4-79No.5A
2900 12.0
13.4
14.8
16.2
17.6
19.1
21.2
23.3
3334
3256
3217
3099
2981
2903
2471
2001
9100
10200
11250
12350
13410
14480
16100
17720
Y160M2-2
(B35)
15
1450 6.0
6.7
7.4
8.1
8.8
9.1
10.6
11.7
834
814
804
775
745
726
618
500
4560
5100
5630
6180
6710
7240
8050
8860
Y100L1-4
(B35)
2.2
4-79No.6A
1450 7.4
8.2
9.1
10.0
10.8
11.6
13.0
14.3
1196
1177
1157
1118
1069
1040
892
706
7890
8820
9740
10700
11600
12520
13920
15320
Y132S-4
(B35)
5.5
960 4.9
5.5
6.0
6.6
7.2
7.7
8.6
9.4
530
520
510
490
471
451
402
314
5230
5840
6420
7080
7680
8290
9220
10100
Y100L-6
(B35)
1.5

4-79 Type Centrifugal Fan For Indoor Ventilation In General Factories
4-79 Type Centrifugal Fan For Indoor Ventilation In General Factories
4-79 Type Centrifugal Fan For Indoor Ventilation In General Factories
4-79 Type Centrifugal Fan For Indoor Ventilation In General Factories


Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment

Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch