• China Office Hotline
    0086 533 5201284
  • Vietnam Hotline
    0084 086 9378260
  • Singapore Hotline
    0065 3163 2969
  • Free Consultancy
    info@decent-machinery.com

4-72-12 Type Centrifugal Fan For Smoke Removal and Dust Collection

The T4-72-12 centrifugal fan, an improved T4-72-11 model, features high efficiency and low noise, making it ideal for applications in smoke and dust removal, boiler blasting, and general ventilation in factories and large buildings. It supports right-hand and left-hand rotation, with adjustable outlet positions. This fan handles non-corrosive gases up to 80℃, ensuring smooth operation with minimal vibration. Available in various sizes, the T4-72-12 is perfect for demanding industrial applications, including air and gas transport, providing reliable and efficient performance.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
4-72-12 Type Centrifugal Fan For Smoke Removal and Dust Collection

Overview

The new T4-72-12 centrifugal fan is an improved, redesigned, and developed version of the original T4-72-11 fan. This centrifugal fan offers high efficiency and low noise, with a flat performance curve, a wide effective working range, and a high-efficiency zone. Available in sizes No. 3, 32, 4, 4%, 5, 6, 8, and 10, the installation dimensions match the original T4-72-11, except for the motor, which has been upgraded to a high-efficiency Y series motor.

1) Application

The T4-72-12 fan serves the same purpose as the original T4-72-11 fan, suitable for general ventilation. It is ideal for indoor ventilation in general factories and large buildings, smoke and dust removal, and boiler blasting. This centrifugal fan can handle both input and output gases, such as air and other non-self-igniting, non-corrosive gases harmless to humans. The gas should not contain sticky substances, and dust and hard particles should not exceed 150mg/m³, with a temperature limit of 80℃.

2) Type

The fan is available in right-hand and left-hand rotation. When viewed from the motor end, a right-hand rotation fan's impeller rotates clockwise, denoted as "right." A left-hand rotation fan's impeller rotates counterclockwise, denoted as "left." The fan outlet position is indicated by the casing's outlet angle. T4-72 fans No.3 to No.6 are manufactured in one form and can be adjusted to the required position by the user. The outlet position adjustment range for No.3 to No.32 is 0°~210° in 30° intervals, and for No.4 to No.6, it is 0°~225° in 22.5° intervals. The transmission mode for No.3 to No.6 is A-type. For No.8 to No.10, the outlet is fixed at 0°, 90°, or 180° and must be specified when ordering. The transmission mode for No.8 to No.10 is C-type.

3) Overall Structure

Fans No. 3 to No. 6 consist mainly of impellers, casings, air inlets, and direct-connected motors. Fans No. 8 to No. 10 also include transmission parts.

Impeller: Balanced to ISO international standard G6.3, ensuring minimal vibration and stable operation after dynamic and static balance correction.
Casing: Fans No.3 to No.10 are made in one piece, non-disassemblable, and usable on both sides. The impeller can be removed from either side but cannot be used interchangeably.
Air Inlet: Integral part installed on the fan side, with a curved section parallel to the axial direction for smooth gas entry and minimal loss.
Transmission Part: Comprises the main shaft, bearing box, rolling bearing, and pulley.

4) Performance and Selection

Fan Performance: The fan's performance is indicated by parameters such as flow rate, total pressure, main shaft speed, shaft power, and efficiency, with interrelated parameters.
Fan Selection: The performance listed in the product performance and optional parts table is based on standard conditions. For non-standard conditions, convert the performance to standard conditions using the "fan performance parameter relationship formula" before selecting from the performance table.

The T4-72-12 centrifugal fan, also known as an ID fan or boiler fan, is designed for efficient and reliable operation in industrial applications such as smoke and dust removal, boiler combustion air supply, and general ventilation.
T4-72-12Performance and optional parts of centrifugal fans
Rotating speed /(r/min) Full pressure /Pa flow /(m³/h) Moter
model power/kW
T4-72-12No.3A
2900 1196
1166
1127
1078
1019
951
872
794
1785
2010
2236
2461
2686
2911
3136
3362
Y802-2B35 1.1
1450 304
294
284
265
255
235
216
196
893
1005
1118
1230
1343
1455
1568
1681
Y802-4B35 0.75
T4-72-12No.3.5A
2900 1637
1578
1529
1460
1392
1294
1196
1088
2835
3192
3550
3907
4265
4623
4981
5338
Y90L-2B35 2.2
1450 412
392
382
363
343
323
294
274
1417
1596
1775
1954
2133
2311
2490
2669
Y90S-4B35  
T4-72-12No.4A
2900 2136
2068
1999
1911
1813
1695
1558
1421
4231
4765
5299
5833
6367
6901
7434
7968
Y132S1-2B35 5.5
1450 529
519
500
480
451
421
392
353
2116
2383
2650
2916
3183
3450
3717
3984
Y90S-4B35 1.1
T4-72-12No.4.5A
2900 2695
2617
2528
2421
2293
2146
1970
1793
6025
6785
7545
8305
9065
9825
10585
11346
Y132S2-2B35 7.5
1450 676
657
627
608
578
539
490
451
3012
3392
3773
4153
4533
4913
5293
5673
Y90S-4B35 1.1
T4-72-12 No.5A
2900 3332
3224
3116
2989
2832
2646
2440
2215
8265
9307
10350
11393
12435
13478
14520
15563
Y160M2-2B35 5
1450 833
804
784
745
706
666
608
559
4132
4654
5175
5696
6218
6739
7260
7782
Y100L1-4B35 2.2
T4-72-12 No.6A
1450 1196
1166
1127
1078
1019
951
872
794
7141
8041
8942
9843
10744
11645
12546
13447
Y112M-4B35  
960 529
510
490
470
451
421
382
353
4728
5324
5920
6517
7113
7710
8306
8903
Y100L-6B35 1.5
T4-72-12No.8C
1800 3283
3185
3077
2940
2793
2607
2401
2185
21011
23662
26313
28964
31614
34265
36916
39567
Y225S-4
(B3)
37
1600 2597
2519
2430
2323
2205
2058
1901
1725
18677
21033
23389
25746
28102
30458
32814
35171
Y180L-4
(B3)
22
1250 1588
1539
1480
1421
1343
1254
1156
1058
14591
16432
18273
20114
21955
23795
25636
27477
Y160M-4
(B3)
11
1120 1274
1235
1196
1137
1078
1009
931
843
13074
14726
16372
18022
19671
21321
22970
24619
Y132M-4
(B3)
7.5
1000 1009
980
951
911
862
804
745
676
11673
13146
14618
16091
17564
19036
20509
21982
Y132S-4
(B3)
5.5
900 823
794
764
735
696
657
598
549
10506
11831
13156
14482
15807
17133
18458
19783
Y112M-4
(B3)
4
800 647
627
608
578
549
519
470
431
9338
10517
11695
12873
14051
15229
16407
17585
Y100L2-4
(B3)
3
710 510
500
480
461
431
402
372
343
8288
9333
10379
11425
12470
13516
14561
15607
Y100L1-4
(B3)
2.2
630 402
392
372
363
343
323
294
265
7354
8282
9200
10137
11065
11993
12921
13848
Y100L-6
(B3)
1.5
T4-72-12No.10C
1300 2675
2597
2509
2401
2274
2127
1960
1784
29638
33378
37117
40856
44596
48334
52073
55813
Y225M-4
(B3)
45
1170 2166
2097
2029
1940
1842
1725
1588
1441
26675
30040
33405
36770
40136
43501
46866
50231
Y200L-4
(B3)
30
1040 1715
1656
1607
1539
1460
1362
1254
1137
23711
26702
29693
32685
35676
38667
41659
44650
Y180L-4
(B3)
22
940 1401
1352
1313
1254
1186
1117
1019
931
21431
24135
26838
29542
32246
34949
37653
40357
Y160L-4
(B3)
15
830 1088
1058
1019
980
931
872
794
725
18923
21310
23698
26085
28472
30860
33247
35634
Y160M-4
(B3)
11
740 872
843
813
774
735
686
637
578
16871
19000
21128
23256
25385
27513
29642
31770
Y132M-4
(B3)
7.5
660 686
666
647
617
588
549
510
461
15047
16946
18844
20742
22641
24539
26437
28336
Y132M2-6
(B3)
5.5
580 529
519
500
480
451
421
392
353
13223
14892
16560
18228
19896
21565
23233
24901
Y132M1-6
(B3)
4
520 431
412
402
382
363
343
314
284
11855
13351
14847
16342
17838
19334
20829
22325
Y132S-6
(B3)
3

4-72-12 Type Centrifugal Fan For Smoke Removal and Dust Collection
4-72-12 Type Centrifugal Fan For Smoke Removal and Dust Collection
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment

Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch
Category