• China Office Hotline
    0086 533 5201284
  • Vietnam Hotline
    0084 086 9378260
  • Singapore Hotline
    0065 3163 2969
  • Free Consultancy
    info@decent-machinery.com

35-220t/h Industrial Circulating Fluidized Bed Boiler Centrifugal Fan

The 35-220t/h Circulating Fluidized Bed Boiler Centrifugal Fan series is designed for high efficiency and energy-saving applications in power plants. This centrifugal fan, centrifugal blower, and high-pressure centrifugal fan range includes primary, secondary, and induced draft fans, with robust construction for minimizing dust, ensuring optimal airflow, and extending fan service life.

  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
35-220t/h Industrial Circulating Fluidized Bed Boiler Centrifugal Fan

Application

 

The 35t/h, 75t/h, 130t/h, and 220t/h circulating fluidized bed boilers are characterized by high efficiency, compatibility with a wide range of coal quality, compact size, and minimal environmental pollution. These centrifugal fan and centrifugal blower models are new energy-saving products, which will be a focus of promotion in China in the future. The medium conveyed by the primary and secondary centrifugal fans is air, with a maximum temperature of 80°C. For the induced draft centrifugal fan, the conveyed medium is flue gas, with a maximum temperature of 250°C. A dust removal device must be installed before the induced draft centrifugal fan to minimize dust content. The dust removal efficiency should be no less than 85%, particularly for power plant use.
 

Form


  1. 1. The primary centrifugal fan, secondary centrifugal fan, and induced draft centrifugal fan are all made in single suction type.
  2. 2. A fan with clockwise impeller rotation, viewed from the motor end, is called a right-hand centrifugal fan; a fan with counterclockwise rotation is called a left-hand centrifugal fan.
  3. 3. The positions of the centrifugal fan's air inlet and outlet are indicated by the air inlet angle and the air outlet angle of the casing.
  4. 4. The centrifugal fan drive modes are D type and F type.

Structural characteristics

 

The industrial centrifugal fan is mainly composed of an impeller, a casing, an air inlet, an air intake box, an adjusting door, and a transmission part.

  1.  
  2. 1. Impeller: The primary and secondary centrifugal fan blades are curved, welded between the conical wheel cover and flat wheel disc. The impellers of the induced draft centrifugal fan are backward-inclined single-plate blades (some wing-shaped), with wear-resistant guards and surfacing wear-resistant layers added to prone areas, increasing the strength, rigidity, and service life of the blades. The centrifugal fan impeller undergoes dynamic balancing, ensuring smooth, reliable operation.
  3. 2. Casing: Made of spiral steel plates, the centrifugal blower casing is available in two structural types: an integral non-dismantle casing or an upper and lower dismantle casing along the axis centerline. The induced draft centrifugal fan casing features a thickened spiral plate for added wear resistance.
  4. 3. Air Inlet: The air inlet is convergent, streamlined, and made into an integral structure, fixed with bolts to the centrifugal fan inlet.
  5. 4. Adjustment Door: The adjustment door controls airflow, installed axially in front of the air inlet, with an adjustment range from 0° (fully open) to 90° (fully closed). The adjustment handle is on the right side when viewed from the inlet side. For right-hand centrifugal fans, push the handle from bottom to top to fully open.
  6. 5. Transmission Part: The transmission component consists of a high-quality steel main shaft with rolling bearings. The primary and secondary fans generally use an integral cylindrical bearing box. Smaller induced draft centrifugal fans use an integral bearing box, while larger ones use independent pillow-type bearing boxes. The bearing box contains a pointer thermometer and oil level indicator, using L-AN46 lubricating oil as required. Induced draft fans are equipped with a water-cooling device, and the water consumption varies with temperature, typically 0.5-1m³/h.

Performance and selection

The performance of the primary centrifugal fan, secondary centrifugal fan, and induced draft centrifugal fan is presented in the performance table, focusing on the circulating fluidized bed boiler parameters. If the boiler parameters and process parameters differ, the centrifugal fan can be redesigned or converted based on the provided parameters.

This series of centrifugal fans is ideal for industrial fluidized bed boilers, providing high-pressure centrifugal performance, efficient dust control, and enhanced energy-saving features for power plants and other applications.

No. Rotating Speed/(r/min)   Air Flow /(m³/h) Full Pressure /Pa Fan Power /kW Motor
Model Power /kW
SFYX35-1No.13D
13D 1450  44331  5088  113  Y315M1-4 132 
55038  5065  130 
65693  4290  146  Y315M2-4 160 
76401  4678  160 
87108  4366  173  Y315L-4 185 
97767  4004  185 
108470  3642  196  Y315L2-4 200 
SFYX35-1No.14D
14D 1450  55369  5902  164  Y315-4 185 
68741  5874  188  Y355-4 250 
82051  5706  211 
95423  5427  232 
108796  5063  250 
122109  4644  267  Y355-4 280 
135478  4223  284 
51835  5673  144  Y315M2-4 160 
58214  5282  144 
64792  5177  152 
71271  5116  160 
78341  4970  169  Y315L-4 185 
84820  4724  176 
91299  4331  180 
97779  3858  184 
SFYX35-1ANo.16D
16D 960  54720  3379  92.9  Y315M3-6 32 
67936  3362  106.5 
81089  3266  119.4 
94304  3106  131.2 
107520  2898  141.4  Y355M1-6 160 
120678  2658  151.0 
133890  2418  160.5 
SFGX35-4ANo.7D
7D 2600   11529  6063  32  Y225M-2 45 
 12970  6016  34 
 14411  5905  36 
 15853  5856  38 
 17424  5651  39 
 18865  5398  42 
 20307  4923  42 
 21747  4432  43 
SFYX50-5ANo.17.5D
17.5D 960   89878  4928  215  Y400-4 280 
 106635  5139  245 
 123394  5163  283 
 140141  5192  242 
 156908  5046  367  Y400-6 400 
 173663  4825  398 
 190428  4546  428 

35-220t/h Industrial Circulating Fluidized Bed Boiler Centrifugal Fan
35-220t/h Industrial Circulating Fluidized Bed Boiler Centrifugal Fan
Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch
Category