220t/h Fluidized Bed Boiler Industrial Centrifugal Blower Fan

The 220t/h Fluidized Bed Boiler Centrifugal Blower Fan series (G220, Y220, and R220) is designed for efficient ventilation, exhaust, and secondary air systems in thermal power plants. Handling air up to 80°C and flue gases up to 250°C, this industrial centrifugal fan series provides robust performance with low dust tolerance, making it a reliable choice for energy-efficient industrial applications.
  • Overview
  • Features
  • Parameter
  • Drawing
  • Application
  • Video
  • FAQ
  • Inquiry
  • Other Products
  • Durability: Vinylester resin, UV protection, extended service life.
  • Customizable: Computer strain analysis, G2.5 balance, low vibration risk.
  • Easy Maintenance: Oil bath bearings, heat/corrosion resistant, cost-effective.
  • Professional Team: Expert wind turbine guidance.
  • High aerodynamic efficiency, low noise, corrosion resistance.
  • Medium temp range: -20℃ to 80℃, ≤ humidity, ≤ 100mg/m3 dust content.
  • Durable Fiberglass Build: Ensures long-lasting performance.
  • Ethylene-based fiberglass blades optimize airflow.
220t/h Fluidized Bed Boiler Industrial Centrifugal Blower Fan

Application

 

This 220t/h Centrifugal Blower Fan series is engineered for the ventilation, exhaust, and secondary air supply systems in 220t/h fluidized bed boilers used in thermal power plants. Designed for industrial durability, the series includes high-pressure centrifugal fans (models G220, Y220, and R220) that ensure optimal air and gas circulation under challenging conditions. The G220 and R220 models are specialized for air, tolerating temperatures up to 80°C with dust levels below 100mg/m³. In contrast, the Y220 induced draft fan model is built for handling flue gases, supporting temperatures as high as 250°C with dust concentrations capped at 200mg/m³. These industrial centrifugal fans meet environmental standards and deliver high-efficiency performance. 
 

Form


  1. 1. Single-Suction Configuration: The entire series of ventilation, induced draft, and secondary fans use a single-suction design to support consistent air and gas handling in industrial applications.
  2. 2. Right- and Left-Handed Options: Fans are available in both right-hand and left-hand configurations. Clockwise rotation indicates a right-handed fan, while counterclockwise rotation represents a left-handed fan.
  3. 3. Outlet Positioning: Each centrifugal blower fan’s outlet angle is indicated for easy alignment during installation.
  4. 4. D-Type Transmission: Incorporates coupling transmission for efficient power delivery, enhancing the fan’s reliability and performance under heavy industrial loads.

Structural Characteristics


Built with an emphasis on durability and efficiency, the 220t/h industrial centrifugal blower series consists of key components like impellers, casings, air inlets, regulating doors, and transmission mechanisms.

  1.  
  2. 1. Impeller: Blades welded between a conical arc cover and flat disc, ensuring balanced, smooth operation. For the induced draft fan, high-grade manganese steel increases durability against industrial wear and tear.
  3. 2. Casing: Welded from steel plates into a volute design, providing long-lasting stability and effective air movement for industrial operations.
  4. 3. Air Inlet: A streamlined air inlet design optimizes airflow into the fan and reduces losses, maximizing the centrifugal fan’s operational efficiency.
  5. 4. Regulating Door: Allows precise control over airflow, adjustable from 0° to 90°. Ventilation and secondary fans use calcium-sodium grease, while induced draft fans require high-temperature molybdenum disulfide grease for seamless operation.
  6. 5. Transmission Mechanism: The high-quality steel main shaft and rolling bearing provide robust support. The bearing box includes a thermometer (provided by the user) and an oil level indicator, with L-AN46 system oil for lubrication. A water-cooling system, consuming 1-2m³/h, is also installed for temperature control in high-demand settings.

Performance and Selection


The 220t/h centrifugal fan series is evaluated under standard intake conditions, with performance converted to meet specific operating requirements as needed. This ensures that each industrial centrifugal fan operates at peak efficiency for fluidized bed boiler applications, offering consistent, energy-saving airflow in power plant environments.

These centrifugal blower fans combine durability and energy efficiency, making them an essential component in industrial ventilation systems within power plants and similar facilities.

Model Rotating Speed /(r/min) Air Flow (m³/h)   Full Pressure /Pa Fan Power  /kW Motor Power /kW
G220-1 1450  150120  26935  1639  1800 
168885  26545  1800 
187650  25925  1972  2000 
206415  25210  2158  2240 
225180  24305  2347  2500 
243945  23180  2525  2800 
262710  22085  2702 
G220-2 1450  119670  23155  1123  1250 
134620  22820  1233 
149570  22290  1352  1400 
164520  21675  1479  1600 
179470  20895  1608  1800 
194420  19930  1730 
G220-3 1450  31640  17415  235  315 
39020  17725  282 
46400  17570  326  355 
53780  17105  370  400 
61160  16355  417  450 
68540  15585  467  500 
75920  14715  520  560 
G220-4 1450  100150  20565  835  900 
112670  20270  917  1000 
125190  19795  1005  1120 
137710  19250  1099 
150230  18550  1195 
162750  17690  1286  1250 
175270  16860  1376  1400 
Y220-1 960  356960  9758  1547  1800 
395210  9587  1627 
433460  9242  1689 
471710  8730  1752 
509960  8218  1810  2000 
548210  7620  1870 
Y220-2 960  264480  8430  1055  1120 
296220  8410  1108 
327960  8265  1165  1250 
359700  7970  1210 
391440  7525  1250 
423180  7085  1295  1400 
454920  6565  1340 
Y220-3 960  186790  6687  590  630 
209210  6672  620 
231630  6555  650  710 
254050  6320  677 
276470  5970  700 
298890  5618  725  800 
321310  5210  750 


Asphalt Plant
Boiler Factory
Cement Plant
Kiln Factory
Metallurgical Plant
Oil Exploitation
Power Plant
Casting Plant
Steelworks
Pelletizing Tower
Carbon Black Factory
Sewage Plant
Sewage Treatment
Decent Fan Customer Comment Impellers Dynamic and Static Balance Test Centrifugal Fan Factory Tour
Complete Centrifugal Fan Assembly Guide Centrifugal Fan Laboratory Testing High-Performance Centrifugal Fan Unveiled
Silent and Powerful Centrifugal Fan Advanced Centrifugal Fan Manufacturing Process Decent Machinery Fan Production Revealed

FAQ
Q: What information is required to request a quotation?
A: To provide a quotation, we would need the following parameters: Airflow, Pressure, Power, Voltage, and Temperature.
Q: How long does it take to receive a quotation?
A: How long does it take to receive a quotation?
Q: Can Decent team assist with the installation process?
A: Absolutely! We have extensive experience in providing installation services to numerous customers. Rest assured, we can handle the installation work for you without any issues.
Get In Touch