The G130, Y130, and R130 series industrial fans provide reliable airflow for ventilation, induced draft, and secondary air systems in fluidized bed boilers with a capacity of 130t/h, especially in thermal power generation. Designed to handle air and flue gases, the G130 ventilator and R130 secondary fan operate with air up to 80°C, while the Y130 induced draft fan manages flue gas at up to 250°C. Dust concentrations are limited to 100mg/m³ for air and 200mg/m³ for flue gases, making it ideal for various industrial environments.
This high-efficiency centrifugal fan includes core components such as the impeller, casing, air inlet, regulating door, and transmission mechanism.
| Rotating Speed /(r/min) | Air Flow /(m³/h) | Full Pressure /Pa | Fan Power /kW | Motor | |
| No. | Power /kW | ||||
| Y130-1 | |||||
| 960 | 5220 | 259380 | 686 | Y500-6 | 800 |
| 5330 | 302610 | 781 | |||
| 5160 | 345840 | 827 | 900 | ||
| 4930 | 389070 | 874 | 1000 | ||
| 4600 | 432300 | 911 | |||
| 4100 | 475530 | 938 | |||
| 3440 | 518760 | 937 | |||
| Y130-2 | |||||
| 960 | 186790 | 6687 | 590 | Y450-6 | 630 |
| 209210 | 6672 | 620 | |||
| 231630 | 6555 | 650 | Y500-6 | 710 | |
| 254050 | 6320 | 677 | |||
| 276470 | 5970 | 700 | 800 | ||
| 298890 | 5618 | 725 | |||
| 321310 | 5210 | 750 | |||
| Y130-3 | |||||
| 960 | 161870 | 6080 | 465 | Y450-6 | 500 |
| 181300 | 6060 | 488 | |||
| 200730 | 5950 | 512 | 560 | ||
| 220160 | 5740 | 533 | |||
| 239590 | 5420 | 551 | |||
| 259020 | 5100 | 571 | 630 | ||
| 278450 | 4730 | 591 | |||
| Note: Inlet conditions: atmospheric pressure p = 101325 Pa, gas temperature t = 150°C, gas density ρ = 0.831 kg/m³. | |||||
| Y130-4 | |||||
| 960 | 101670 | 7970 | 357 | Y450-6 | 450 |
| 115220 | 7840 | 395 | |||
| 128770 | 7640 | 435 | |||
| 142320 | 7400 | 478 | Y450-6 | 500 | |
| 155870 | 7090 | 521 | Y450-6 | 560 | |
| 169420 | 6730 | 561 | |||
| 182970 | 6380 | 604 | Y450-6 | 630 | |
|
Note: 1. Inlet conditions: atmospheric pressure p = 101325 Pa, temperature t = 140°C, medium density ρ = 0.851 kg/m³. 2. When atmospheric pressure pa = 81600 Pa (612 mmHg), the motor for operating point 6 is Y450-6, 500 kW. |
|||||














|
|
|
|