The layout of supply and return air openings in central air conditioning construction

Posted on 2023-10-20


Floor supply and ceiling supply are both for the bidirectional flow fresh air system of piped distribution. This kind of fresh air system needs to deliver and return air through the system. In the ceiling supply mode, the fresh air and polluted air of the fresh air system are both delivered through the air openings located on the ceiling. In the floor supply mode, the supply air is achieved by the air openings located on the floor or low-end wall, and the return air is completed by the air openings on the ceiling. With adequate air volume to meet the demand, both the ceiling supply mode and the floor supply mode perform well. However, the latter is slightly better, so it should be given priority under favorable conditions.
 
When using side-mounted air outlets, or ceiling-mounted air outlets, the delivery air speed in winter must be above 2.5m/s to avoid the phenomenon of hot air staying and stagnating on the ceiling. Therefore, it is sometimes necessary to ensure that the ventilation frequency of the room is 5-8 times per hour. The air flow velocity in the area where people work and stay indoors should be controlled within the range of 0.5m/s. If the air outlet is installed at the upper part of the wall, when the air flow blows towards the beams or the decoration ceiling, it is necessary to move the position of the air outlet downward as much as possible, or use horizontally adjustable louvers to avoid the air flow hitting the beams.



The number of supply air outlets and return air outlets depends on the size of the room. For ordinary residential buildings, one supply and one return air outlet per room is sufficient when installing a home ventilation system. For medium-sized areas such as villas, living rooms, conference rooms, and offices, it is necessary to appropriately increase the number of air outlets. In ordinary homes, study rooms and other rooms can be installed according to actual use. In short, it is only necessary to meet the first requirement.
 
Toilet and kitchen have strong particularity. Both will produce highly polluted and humid gases in a short period of time. If supply air outlets are installed here, these polluted gases will be sent to other rooms. If return air outlets are installed here, these gases will be sent to the interior of the new air system, increasing the load of the new air system and affecting its effect. Therefore, it is recommended that neither supply nor return air outlets should be installed in the toilet and kitchen, but two independent exhaust fans should be installed.
 
It is recommended to install the living room supply air outlet in a location close to the pollution source, such as near the kitchen or near the door, and the return air outlet can be installed diagonally with the supply air outlet.


The number of supply air outlets and return air outlets depends on the size of the room. For ordinary residential buildings, one supply and one return air outlet per room is sufficient when installing a home ventilation system. For medium-sized areas such as villas, living rooms, conference rooms, and offices, it is necessary to appropriately increase the number of air outlets. In ordinary homes, study rooms and other rooms can be installed according to actual use. In short, it is only necessary to meet the first requirement.
 
Toilet and kitchen have strong particularity. Both will produce highly polluted and humid gases in a short period of time. If supply air outlets are installed here, these polluted gases will be sent to other rooms. If return air outlets are installed here, these gases will be sent to the interior of the new air system, increasing the load of the new air system and affecting its effect. Therefore, it is recommended that neither supply nor return air outlets should be installed in the toilet and kitchen, but two independent exhaust fans should be installed.
 
It is recommended to install the living room supply air outlet in a location close to the pollution source, such as near the kitchen or near the door, and the return air outlet can be installed diagonally with the supply air outlet.



In general, corridors and other areas do not require supply or return air outlets based on the room area. The ventilation conditions in the basement are poor, so both supply and return air outlets need to be installed. When installing, the location of the air outlets should be carefully considered according to the function of the basement.
 
The ground supply and ceiling return mode is more effective than the ceiling supply and return mode, but the ground supply and ceiling return mode requires higher ceiling height and the ground supply air outlet is easily polluted. Therefore, the wall exhaust air mode is recommended when using ground supply air.
 
The distance between supply air outlets and return air outlets should be as far as possible to achieve the purification effect.
Hot News
  • DECENT MACHINERY Deepens Overseas Mining Cooperation with High-standard Customized Fan Solutions 2026-09-09 DECENT MACHINERY Deepens Overseas Mining Cooperation with High-standard Customized Fan Solutions Upholding the philosophy of quality-oriented development and customer-centric service, DECENT MACHINERY continues to expand its global mining equipment market footprint. Recently, the company has achieved in-depth and repeated cooperation with a high-standard mining client in Southeast Asia, relying on reliable product quality, rigorous safety standards and transparent full-cycle service, further ...
  • DECENT MACHINERY Delivers Custom‑Built Tunnel Fans for Leading Underground Gold Mine Project in Cent... 2026-09-08 DECENT MACHINERY Delivers Custom‑Built Tunnel Fans for Leading Underground Gold Mine Project in Central Asia DECENT MACHINERY continues to deliver robust custom‑tailored tunnel ventilation solutions for a flagship underground gold mining operation across Central Asia, addressing extreme underground operational challenges within complex deep‑mine environments. The region’s premier underground gold mine has long grappled with persistent operational bottlenecks stemming from narrow underground drifts, kilom...
  • DECENT MACHINERY Deepens European Strategic Cooperation After 3 Years of Dedicated Communication 2026-09-07 DECENT MACHINERY Deepens European Strategic Cooperation After 3 Years of Dedicated Communication Recently, DECENT MACHINERY’s overseas business team held an in-depth face-to-face business meeting and friendly dinner negotiation with long-term European clients in Shanghai. Both parties reviewed the whole progress of project communication, confirmed the official cooperation order, and conducted in-depth discussions on future multi-dimensional strategic cooperation.   The project cooperation bet...
  • New Order Secured: Multistage Centrifugal Fans for a Key Southeast Asia Project 2026-09-04 New Order Secured: Multistage Centrifugal Fans for a Key Southeast Asia Project We are delighted to announce that Decent Machinery has won a new contract for multistage centrifugal fans. This equipment will be deployed in a major China‑aided landmark project in Southeast Asia.   The end customer is a global leading manufacturer of power semiconductors. The multistage centrifugal fans are designed for the factory’s wastewater treatment system, serving as core aeration equipmen...
Category
Get in Touch